4.6 Article

Deep learning-based fully automated Z-axis coverage range definition from scout scans to eliminate overscanning in chest CT imaging

期刊

INSIGHTS INTO IMAGING
卷 12, 期 1, 页码 -

出版社

SPRINGER
DOI: 10.1186/s13244-021-01105-3

关键词

CT; Radiation dose; Overscanning; Deep learning; Chest imaging

资金

  1. Euratom research and training programme 2019-2020 Sinfonia project u [945196]

向作者/读者索取更多资源

Despite the prevalence of chest CT in the clinic, concerns about unoptimized protocols delivering high radiation doses to patients still remain. This study aimed to assess the additional radiation dose associated with overscanning in chest CT and to develop an automated deep learning-assisted scan range selection technique to reduce radiation dose to patients. The DL-based approach resulted in errors of 0.08 +/- 1.46 and - 1.5 +/- 4.1 mm in superior and inferior directions, respectively, demonstrating a reduction in unnecessary radiation exposure to patients.
Background Despite the prevalence of chest CT in the clinic, concerns about unoptimized protocols delivering high radiation doses to patients still remain. This study aimed to assess the additional radiation dose associated with overscanning in chest CT and to develop an automated deep learning-assisted scan range selection technique to reduce radiation dose to patients. Results A significant overscanning range (31 +/- 24) mm was observed in clinical setting for over 95% of the cases. The average Dice coefficient for lung segmentation was 0.96 and 0.97 for anterior-posterior (AP) and lateral projections, respectively. By considering the exact lung coverage as the ground truth, and AP and lateral projections as input, The DL-based approach resulted in errors of 0.08 +/- 1.46 and - 1.5 +/- 4.1 mm in superior and inferior directions, respectively. In contrast, the error on external scout views was - 0.7 +/- 4.08 and 0.01 +/- 14.97 mm for superior and inferior directions, respectively.The ED reduction achieved by automated scan range selection was 21% in the test group. The evaluation of a large multi-centric chest CT dataset revealed unnecessary ED of more than 2 mSv per scan and 67% increase in the thyroid absorbed dose. Conclusion The proposed DL-based solution outperformed previous automatic methods with acceptable accuracy, even in complicated and challenging cases. The generizability of the model was demonstrated by fine-tuning the model on AP scout views and achieving acceptable results. The method can reduce the unoptimized dose to patients by exclunding unnecessary organs from field of view.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据