4.7 Article

Comparable Efficacy in Ischemic and Non-Ischemic ICD Recipients for the Primary Prevention of Sudden Cardiac Death

期刊

BIOMEDICINES
卷 9, 期 11, 页码 -

出版社

MDPI
DOI: 10.3390/biomedicines9111595

关键词

primary prevention of sudden cardiac death; non-ischemic cardiomyopathy; ischemic cardiomyopathy; appropriate ICD therapy; mortality rate comparison

向作者/读者索取更多资源

This single-center study focused on the cardiovascular outcomes in ischemic and non-ischemic heart failure patients who received ICD therapy for the prevention of sudden cardiac death. The results showed similar rates of cardiovascular and all-cause mortality between ICMP and NICMP patients, as well as comparable rates of recurrent ventricular tachyarrhythmias and appropriate ICD therapies.
(1) Background: In patients suffering from heart failure, the main causes of death are either hemodynamic failure, or ventricular arrhythmias. The only tool to significantly reduce arrhythmic sudden death is the implantable cardioverter defibrillator (ICD), but not all patients benefit to the same extent from these devices. (2) Methods: The primary outcome of this single-center study was defined as cardiovascular death in patients with ischemic and non-ischemic heart failure who have benefited from ICD therapy. The secondary outcomes were death from any cause, sudden cardiac death, ICD-related therapies (appropriate antitachycardia pacing or shock therapy for ventricular tachycardia or fibrillation) and recurrences of ventricular tachyarrhythmias. (3) Results: A total of 403 consecutive ICD recipients-symptomatic heart failure patients with ICD for the primary prevention of sudden cardiac death-were included retrospectively: 59% ischemic cardiomyopathy (ICMP) and 41% non-ischemic cardiomyopathy (NICMP) patients. Within a median follow-up period of 36 months, the incidence of cardiovascular mortality was not significantly different in patients with NICMP and ICMP: the primary outcome had occurred in 9 patients (5.4%) in the NICMP group and in 14 patients (5.9%) in the ICMP group (hazard ratio 1; 95% confidence interval (CI) 0.45 to 2.28; p = 0.97). All-cause mortality occurred in 14 of 166 patients (8.4%) in the NICMP group and 18 of 237 patients (7.6%) in the ICMP group. Sudden cardiac death occurred in two patients (1.2%) in the NICMP group and in four patients (1.7%) in the ICMP group (hazard ratio 0.71; 95% CI, 0.13 to 3.88; p = 0.69). The rate of appropriate device therapies was comparable in both groups. (4) Conclusions: In this study, ICD implantation for primary prevention of sudden cardiac death in patients with symptomatic systolic heart failure was associated with similar rates of cardiovascular and all-cause mortality in patients with ischemic heart disease, and in patients with heart failure from other causes. NICMP and ICMP showed comparable rates of recurrent ventricular tachyarrhythmias and appropriate ICD therapies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据