Indirect evaporative cooling system; Cross-flow configuration; Numerical modeling; Condensation; Wettability factor
资金
- Natural Science Fund Project in Jiangsu Province [BK20201294]
- Key Research and Development Program of Jiangsu Province [BE2019088]
This study investigates the heat and mass transfer process within an indirect evaporative cooling system in hot and humid climates. A numerical model is developed and validated to predict condensation in different operating conditions. The wettability factor significantly affects the condensation process, reducing condensation when decreased. Increasing the secondary air inlet velocity enhances the condensation process and improves humidity ratio and cooling capacity.
This paper presents an investigation on the process of heat and mass transfer within an indirect evaporative cooling (IEC) system with a cross-flow arrangement for hot and humid climates. For this purpose, a numerical model based on energy and mass balance within IEC has been developed that predicts condensation from the primary air. The numerical model is validated employing numerical and experimental data from the literature with a perfect agreement. Precise simulations are executed to observe and investigate the condensation cases, including (non, partial, and full condensation) in the dry channel. The performance of the IEC system is evaluated under variable operating conditions, including primary and secondary air velocity, inlet temperature, humidity ratio, and wettability factor. The results noted that the three condensation states in the primary air channel depend on operating conditions such as humidity ratio, inlet temperature, velocity, and wettability factor. Besides, the wettability factor greatly affects the condensation and cooling process; when the factor is reduced to 0.5, condensation is delayed; and the amount was reduced to 0.52 g/kg instead of 1.32 g/kg when the factor is 1. Also, the average temperature at the outlet increased from 20.2 degrees C to 23.4 degrees C when the factor was reduced from 1 to 0.5, respectively. Furthermore, increasing the secondary air inlet velocity enhances the condensation process as the state changes from non-condensing to condensing and the humidity ratio decreased from 14.65 g/kg to 13.7 g/kg; besides, the temperature difference and cooling capacity are also improved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据