4.6 Article

Gold and Platinum Nanoparticle-Functionalized TiO2 Nanotubes for Photoelectrochemical Glucose Sensing

期刊

ACS OMEGA
卷 7, 期 2, 页码 2474-2483

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsomega.1c06787

关键词

-

资金

  1. Finance Science and Technology Project of Hainan Province [2019RC114, 2019RC221, 820RC647, ZDKJ2021029, ZDYF2021SHFZ068]
  2. Hainan Province Clinical Medical Center
  3. National Natural Science Foundation of China [51762012, 51862006, 81860373, 81902154, 82060386]
  4. CAMS Innovation Fund for Medical Sciences [2019-I2M-5-023]
  5. Key Laboratory Open Project Fund of Emergency and Trauma of Ministry of Education [KLET-202008]

向作者/读者索取更多资源

A highly sensitive and stable enzymatic glucose photoelectrochemistry biosensor has been designed and fabricated. The introduction of Pt nanoparticles greatly improves the sensitivity of the glucose biosensor. This is of great significance for designing high-performance enzyme biosensors.
Developing stable photoelectrochemistry (PEC) glucose biosensors with high sensitivity and a low detection limit is highly desirable in the biosensor field. Herein, a highly sensitive and stable enzymatic glucose PEC biosensor is rationally designed and fabricated using a TiO2NTs/Au/Pt/GOx electrode. First, we prepared one-dimensional TiO2 nanotube arrays which could realize the orthogonalization of the light-incident direction and the carrier diffusion direction via anodization. Subsequently, we used the method of photoassisted deposition for anchoring Pt nanoparticles on TiO2NTs after electrodepositing Au nanoparticles. Among them, Au nanoparticles promote light absorption via the surface plasmon resonance effect and the separation of photogenerated carriers through forming a Schottky junction. Moreover, the Pt nanoparticles on the electrode surface can react with hydrogen peroxide (H2O2) generated from glucose (Glu) oxidation by glucose oxidase (GOx), accelerating the electron-transfer process during glucose oxidation and greatly improving the sensitivity of the glucose biosensor. As a result, TiO2NTs/Au/Pt/GOx exhibited excellent PEC performance, achieving a high sensitivity of 81.93 mu A mM(-1) cm(-2) and a low detection limit (1.39 mu M), far exceeding the performance of TiO2NTs/M/GOx (M = Au, Pt). Therefore, the introduction of Pt nanoparticles as active substances to promote enzymatic reactions is important for designing high-performance enzyme biosensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据