4.7 Article

Simple and Sensitive Method for the Quantitative Determination of Lipid Hydroperoxides by Liquid Chromatography/Mass Spectrometry

期刊

ANTIOXIDANTS
卷 11, 期 2, 页码 -

出版社

MDPI
DOI: 10.3390/antiox11020229

关键词

lipid hydroperoxide; unsaturated fatty acids; 2-methoxypropene; chemical derivatization; liquid chromatography; mass spectrometry; human serum; lipoprotein oxidation

资金

  1. JSPS Kakenhi [17H01879, 18K07434, 19H03117, 19K07861m, 19k20174, 21K1481201]
  2. Faculty of Health Science, Hokkaido University [870411Q]
  3. Grants-in-Aid for Scientific Research [19H03117, 19K20174, 18K07434, 17H01879] Funding Source: KAKEN

向作者/读者索取更多资源

Lipid hydroperoxides (LOOH) are important products of lipid oxidation and have adverse effects on human health. In this study, a sensitive and selective analytical method for determining LOOH was developed. The method involved chemical synthesis and chemical labeling to improve stability and ionization efficiency. Application of the method to human serum samples revealed linoleic acid hydroperoxide and oleic acid hydroperoxide as the major LOOHs. Overall, the validated LC-MS/MS methodology provides an enhanced detection and rapid separation tool for quantifying multiple LOOHs in lipid peroxidation, with potential diagnostic applications.
Lipid hydroperoxides (LOOH) are the initial products of the peroxidation of unsaturated lipids and play a crucial role in lipid oxidation due to their ability to decompose into free radicals and cause adverse effects on human health. Thus, LOOHs are commonly considered biomarkers of oxidative stress-associated pathological conditions. Despite their importance, the sensitive and selective analytical method for determination is limited, due to their low abundance, poor stability, and low ionizing efficiency. To overcome these limitations, in this study, we chemically synthesized eight fatty acid hydroperoxides (FAOOH), including FA 18:1-OOH, FA 18:2-OOH, FA 18:3-OOH, FA 20:4-OOH, FA 20:5-OOH, FA 22:1-OOH, FA 22:6-OOH as analytes, and FA 19:1-OOH as internal standard. Then, they were chemically labeled with 2-methoxypropene (2-MxP) to obtain FAOOMxP by one-step derivatization (for 10 min). A selected reaction monitoring assisted targeted analytical method was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). The MxP-labelling improved the stability and enhanced the ionization efficiency in positive mode. Application of reverse-phase chromatography allowed coelution of analytes and internal standards with a short analysis time of 6 min. The limit of detection and quantification for FAOOH ranged from 0.1-1 pmol/mu L and 1-2.5 pmol/mu L, respectively. The method was applied to profile total FAOOHs in chemically oxidized human serum samples (n = 5) and their fractions of low and high-density lipoproteins (n = 4). The linoleic acid hydroperoxide (FA 18:2-OOH) and oleic acid hydroperoxide (FA 18:1-OOH) were the most abundant FAOOHs in human serum and lipoproteins. Overall, our validated LC-MS/MS methodology features enhanced detection and rapid separation that enables facile quantitation of multiple FAOOHs, therefore providing a valuable tool for determining the level of lipid peroxidation with potential diagnostic applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据