Experimental study on power generation plant of a 1 kW small-scale Organic Rankine Cycle system using R290

期刊

ENERGY SCIENCE & ENGINEERING
卷 10, 期 3, 页码 740-751

出版社

WILEY
DOI: 10.1002/ese3.1049

关键词

cold energy utilization; LNG; operational parameters; ORC power generation; R290

资金

  1. Science and Technology Commission of Shanghai Municipality [18040501800]
  2. National Natural Science Foundation of China [51706129, 51779136]

向作者/读者索取更多资源

This work presents an experimental investigation of a small-scale cryogenic Organic Rankine Cycle (ORC) power generation plant. The results show that increasing pressure drop and heat source temperature can improve system performance to some extent, with pressure drop exhibiting sensitivity to heat source temperature. The expander gross output power reaches its peak value when the heat source and heat sink are best matched.
This work presents an experimental investigation of a small-scale cryogenic Organic Rankine Cycle (ORC) power generation plant for cold energy utilization using scroll expander and R290. The fresh water and liquid nitrogen were used as heat source and heat sink, respectively. Furthermore, expander gross output power and isentropic efficiency, system thermal efficiency, and cold energy utilization efficiency were calculated as a principle to evaluate the overall system performance. The experimental results demonstrate that increasing pressure drop and heat source temperature will benefit the system performance in some extent, and the pressure drop exhibits a relative sensitivity to heat source temperature about the system performance. Moreover, the expander gross output power will get the peak value while the heat source and heat sink in the best matching. When the mass flow rate of liquid nitrogen at 120 kg/h, optimum pressure drop is 1.02 Mpa, and the corresponding expander gross output power, thermal efficiency, and cold energy utilization efficiency were 638.2W, 0.0586, and 0.0976, respectively. The optimum heat source temperature is 50celcius under liquid nitrogen mass flow rate of 120 kg/h, and the corresponding expander gross output power, thermal efficiency, and cold energy utilization efficiency were 674.2 W, 0.0594, and 0.099, respectively.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据