4.5 Article

Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes

期刊

出版社

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/tvst.11.1.23

关键词

optical coherence tomography angiography; glaucoma; artifact; image quality

资金

  1. High-Level Hospital Construction Project, Zhongshan Ophthalmic Center, Sun Yatsen University [303020104]
  2. National Natural Science Foundation of China [82070955, 82000901]

向作者/读者索取更多资源

This study evaluated the frequency of artifacts in swept-source optical coherence tomography angiography (SS-OCTA) and identified factors that influence the presence of these artifacts. The results revealed that glaucomatous eyes had a higher prevalence of SS-OCTA image artifacts compared to normal eyes. The image quality score was found to be an imperfect tool for identifying these artifacts.
Purpose: To evaluate the frequency of and identify the factors that influence the artifacts of swept-source optical coherence tomography angiography (SS-OCTA) in glaucomatous and normal eyes. Methods: Artifacts of OCTA images of open-angle glaucoma (OAG) and normal subjects were analyzed using SS-OCTA. Univariate and multivariate logistic regression analyses were performed to evaluate the association of age, sex, best-corrected visual acuity, axial length (AL), intraocular pressure, presence and severity of OAG, and image quality score (IQS) with the presence of artifacts. Results: Images from 4426 subjects were included in the study. At least one type of artifact was present in 24.54% of the images. The most common artifacts were occurrence of motion (705 eyes, 15.93%), followed by defocus (628 eyes, 14.19%), decentration (134 eyes, 3.03%), masking (62 eyes,1.40%), and segmentation errors (23 eyes, 0.52%). Multivariate logistic analyses showed that the presence of OAG (odds ratio [OR] = 2.71; 95% confidence interval [CI], 2.09-3.51; P < 0.001), female sex (OR = 1.34; 95% CI, 1.12-1.61; P = 0.001), longer AL (OR = 1.09; 95% CI, 1.02-1.17; P = 0.017), and IQS < 40 (OR = 3.75; 95% CI, 3.15-4.48; P < 0.001) were significantly associated with higher odds for the presence of any artifact. The IQS had poor performance for detecting artifacts, with an area under the curve of 0.723, sensitivity of 73.04%, and specificity of 62.53%. Conclusions: OAG eyes had more SS-OCTA image artifacts than normal eyes. IQS is an imperfect tool for identifying artifacts. Translational Relevance: Special attention should be paid to the effect of artifacts when using SS-OCTA in the clinical setting to assess vascular parameters in patients with glaucoma.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据