4.1 Article

Appropriate chamber deployment time for separate quantification of CH4 emissions via plant and ebullition from rice paddies using a modified closed-chamber method

期刊

JOURNAL OF AGRICULTURAL METEOROLOGY
卷 78, 期 1, 页码 41-45

出版社

SOC AGRICULTURAL METEOROLOGY JAPAN
DOI: 10.2480/agrmet.D-21-00033

关键词

Bubbling frequency; CH 4 flux; High time resolution; Measurement time; Portable gas analyzer

资金

  1. JSPS KAKENHI [JP19K22921, JP19H03096, JP20J40189, JPNP18016]
  2. New Energy and Industrial Technology Development Organization (NEDO) [JPNP18016]

向作者/读者索取更多资源

A modified closed-chamber method was developed to estimate CH4 emissions from rice paddies. The study found that the estimated flux was sensitive to time length with short closure times but became less sensitive with longer closure. The minimum time length required for accurate flux measurement varied depending on the frequency of bubbling events.
A modified closed-chamber method for estimating total, plant-mediated, and bubbling (ebullition) emissions of CH4 from rice paddies has been developed to use high-time-resolution CH4 concentration data (-1 Hz) obtained by a spectroscopic mobile gas analyzer. Here we aimed at determining an appropriate minimum time length of chamber closure for accurate flux measurement by investigating 3255 datasets obtained from a 2-year field survey. To investigate the minimum time length for each chamber measurement, we generated a series of datasets from each measurement: by setting the hypothetical termination time of the chamber closure ahead in 1-min intervals, we obtained various chamber CH4 concentration time series with different durations of chamber closure, and separately estimated CH4 emissions via rice plants and bubbling from each. The estimated flux was sensitive to time length with short closure times, but became less sensitive with longer closure. We defined the minimum time length at which the difference in estimated flux between adjacent time windows was small enough ( 10% of plant-mediated emission). The estimated minimum time length differed from one measurement to another, but 10 min was sufficient for 99% of cases. Detailed analysis showed a positive correlation between minimum time length and frequency of bubbling events; the time length needed to be longer as bubbling events became more frequent. From this relationship, we computed the appropriate chamber-duration time as a function of bubbling frequency. In the absence of ebullition, 4-5 min was sufficient, but as the bubbling frequency increased to 2.5 times per minute 15-20 min was necessary for accurate pathway-dependent flux measurements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据