4.6 Article

Force Measurement with a Strain Gauge Subjected to Pure Bending in the Fluid-Wall Interaction of Open Water Channels

期刊

APPLIED SCIENCES-BASEL
卷 12, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/app12031744

关键词

small force; load; instrumental signal; two-point bending test; strain gauge; calibration equation

资金

  1. Universidad del Bio-Bio, Chile [VRAPROYE-UBB2055]
  2. [ANID/FONDAP/15130015]

向作者/读者索取更多资源

This research presents an experimental method using strain gauges to measure small forces in fluid-wall interaction. The results showed a significant linear relationship between the strain gauge and the load, allowing for accurate measurement of small forces.
Featured Application This research has specific applications in the measurement of forces of small magnitude, which occur in the fluid-wall interaction, through a non-destructive technique that allows for measuring the shear stress in open water channels. An experimental method to measure forces of small magnitude with a strain gauge as a force sensor in the fluid-wall interaction of open water channels is presented. Six uniaxial strain gauges were employed for this purpose, which were embedded across the entire sensing area and subjected to pure bending, employing two-point bending tests. Sixteen two-point bending tests were performed to determine the existence of a direct relationship between the load and the instrument signal. Furthermore, a regression analysis was used to estimate the parameters of the model. A data acquisition system was developed to register the behavior of the strain gauge relative to the lateral displacement induced by the loading nose of the universal testing machine. The results showed a significant linear relationship between the load and the instrumental signal, provided that the strain gauge was embedded between 30% and 45% of the central axis in the sensing area of the sensor (R-2 > 0.99). Thus, the proposed sensor can be employed to measure forces of small magnitude. Additionally, the linear relationship between the load and the instrumental signal can be used as a calibration equation, provided that the strain gauge is embedded close to the central axis of the sensing area.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据