4.8 Article

Raman Nanotags-Guided Intraoperative Sentinel Lymph Nodes Precise Location with Minimal Invasion

期刊

ADVANCED SCIENCE
卷 9, 期 2, 页码 -

出版社

WILEY
DOI: 10.1002/advs.202102405

关键词

biotoxicity evaluations; gap-enhanced Raman tags (GERTs); sentinel lymph node (SLN); surgery windows; tracer

资金

  1. National Natural Science Foundation of China [81871401, 82103695, 82173115]
  2. Science and Technology Commission of Shanghai Municipality [19441905300, 20DZ2201600, 21511102100]
  3. Shanghai Collaborative Innovation Center for Translational Medicine [TM201908]
  4. Shanghai Municipal Key Clinical Specialty, the Shanghai Rising Stars of Medical Talent Youth Development Program Youth Medical Talents-Specialist Program [2018-15]
  5. Clinical Research Plan of SHDC [SHDC2020CR3003A]
  6. Shanghai Jiao Tong University [YG2019QNA28]
  7. Nurturing Fund of Renji Hospital [PYMDT-002, PY2018-IIC-01, PYIII20-09]
  8. Shanghai Key Laboratory of Gynecologic Oncology

向作者/读者索取更多资源

The nontoxic Raman nanoparticle tracer GERTs allows for accurate identification of SLNs within 10 minutes in white New Zealand rabbit models, providing surgeons with over 4 hours to distinguish between SLNs and 2nd LNs. Additionally, GERTs have ultrahigh sensitivity, allowing for preoperative positioning information for minimally invasive surgery with no significant toxicity demonstrated in biosafety evaluations.
The accurate positioning of sentinel lymph node (SLN) by tracers during surgery is an important prerequisite for SLN biopsy. A major problem of traditional tracers in SLN biopsy is the short surgery window due to the fast diffusion of tracers through the lymphatics, resulting in a misjudgment between SLN and second echelon lymph node (2(nd) LN). Here, a nontoxic Raman nanoparticle tracer, termed gap-enhanced Raman tags (GERTs), for the accurate intraoperative positioning of SLNs with a sufficient surgical time window is designed. In white New Zealand rabbit models, GERTs enable precise identification of SLNs within 10 min, as well as provide the surgeon with a more than 4 h time window to differentiate SLN and 2(nd) LN. In addition, the ultrahigh sensitivity of GERTs (detection limit is 0.5 x 10(-12) m) allows detection of labeled SLNs before surgery, thereby providing preoperative positioning information for minimally invasive surgery. Comprehensive biosafety evaluations carried out in the context of the Food and Drug Administration and International Standard Organization demonstrate no significant toxicity of GERTs, which supports a promising clinical translation opportunity of GERTs for precise SLN identification in breast cancer.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据