Use of Microscale Thermophoresis to Measure Protein-Lipid Interactions

期刊

出版社

JOURNAL OF VISUALIZED EXPERIMENTS
DOI: 10.3791/60607

关键词

-

资金

  1. National Science Foundation [MCB 1818310]
  2. Chemical Biology Core Facility/Protein Crystallography Unit at the H. Lee Moffitt Cancer Center [NIH/NCI: P30-CA076292]

向作者/读者索取更多资源

Determining the binding affinity of lipids to proteins is crucial for understanding protein-lipid interactions. Traditional methods like SPR and ITC have limitations, such as cost and time consumption. MST offers a fast and cost-effective alternative, using small amounts of sample to obtain binding curves.
The ability to determine the binding affinity of lipids to proteins is an essential part of understanding protein-lipid interactions in membrane trafficking, signal transduction and cytoskeletal remodeling. Classic tools for measuring such interactions include surface plasmon resonance (SPR) and isothermal titration calorimetry (ITC). While powerful tools, these approaches have setbacks. ITC requires large amounts of purified protein as well as lipids, which can be costly and difficult to produce. Furthermore, ITC as well as SPR are very time consuming, which could add significantly to the cost of performing these experiments. One way to bypass these restrictions is to use the relatively new technique of microscale thermophoresis (MST). MST is fast and cost effective using small amounts of sample to obtain a saturation curve for a given binding event. There currently are two types of MST systems available. One type of MST requires labeling with a fluorophore in the blue or red spectrum. The second system relies on the intrinsic fluorescence of aromatic amino acids in the UV range. Both systems detect the movement of molecules in response to localized induction of heat from an infrared laser. Each approach has its advantages and disadvantages. Label-free MST can use untagged native proteins; however, many analytes, including pharmaceuticals, fluoresce in the UV range, which can interfere with determination of accurate K-D values. In comparison, labeled MST allows for a greater diversity of measurable pairwise interactions utilizing fluorescently labeled probes attached to ligands with measurable absorbances in the visible range as opposed to UV, limiting the potential for interfering signals from analytes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据