4.3 Article

Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study

期刊

出版社

SPRINGER
DOI: 10.1007/s10554-016-1011-0

关键词

Computed tomography; Perfusion; Analysis; Myocardium; Temporal averaging

资金

  1. Heisenberg Program of the DFG [DE 1361/14-1]
  2. FP7 Program of the European Commission [603266-2, HEALTH-2012.2.4.-2]
  3. European Regional Development Fund [20072013 2/05, 20072013 2/48]
  4. German Heart Foundation/German Foundation of Heart Research [F/23/08, F/27/10]
  5. German Research Foundation (DFG) [01KG1013, 01KG1110, 01KG1210]
  6. German Federal Ministry of Education and Research (BMBF) [01KG1013, 01KG1110, 01KG1210]
  7. GE Healthcare
  8. Bracco
  9. Guerbet
  10. Toshiba Medical Systems
  11. Cardiac MR Academy Berlin
  12. Bayer (Schering-Berlex)

向作者/读者索取更多资源

To assess the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis. We included 30 patients with suspected or known coronary artery disease (CAD) who underwent 320-row coronary CT angiography (CTA) and myocardial CTP. Out of these, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI). All CTP examinations were initiated after 3 min of intravenous infusion of adenosine (140 A mu g/kg/min) and were performed dynamically covering the entire heart every heart beat over a period of 20 +/- 3 heart beats. Temporal averaging for dynamic CTP visualisation was analysed for the combination of two, three, four, six, and eight consecutive 3D datasets. Input time attenuation curves (TAC) were delivered from measurement points in the centre of the left ventricle. In all 30 patients, myocardial 4D CTP was feasible and temporal averaging was successfully implemented for all planned combinations of 3D datasets. Temporal averaging of three consecutive 3D datasets showed best performance in the analysis of all CTP image quality parameters: noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and diagnostic accuracy with an improvement of SNR and CNR by a factor of 2.2 +/- 1.3 and 1.3 +/- 0.9. With increasing level of temporal averaging, the input TACs became smoother, but also shorter. Out of the 11 perfusion defects detected with MR MPI, 9 defects were also visible on the 4D CTP images. Whole-heart CTP of the myocardium is feasible and temporal averaging of dynamic datasets improves quantitative image quality parameters and visualization of perfusion defects while further studies are needed to assess its added value for quantification of perfusion parameters.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据