4.5 Article

Sensing mammographic density using single-sided portable Nuclear Magnetic Resonance

期刊

SAUDI JOURNAL OF BIOLOGICAL SCIENCES
卷 29, 期 4, 页码 2447-2454

出版社

ELSEVIER
DOI: 10.1016/j.sjbs.2021.12.022

关键词

NMR; MRI; Relaxation time; Breast cancer; Mammographic density

类别

资金

  1. Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah DSR [RG-87-135-42]

向作者/读者索取更多资源

This research paper introduces a quantitative approach to sensing mammographic density using single-sided portable Nuclear Magnetic Resonance (NMR). The study validates the effectiveness of three main NMR techniques and finds strong correlations and agreements between them in measuring mammographic density.
This research paper presents a quantitative approach to sensing mammographic density (MD) using single-sided portable Nuclear Magnetic Resonance (NMR). It focuses on three main techniques: spin-lattice relaxation (recovery) time (T-1), spin-spin relaxation (decay) time (T-2), and Diffusion (D) techniques by testing whether or not the aforementioned techniques are in agreement with the gold standard and with each other when used for scanning breast tissue specimens with a variety of mammographic densities (MDs). The high mammographic density (HMD), intermediate MD, and low mammographic density (LMD) regions of each slice were identified according to the mammogram images. Subsequently, the grayscale values for these regions were quantified. One region was measured from the first sample while the remaining ones were measured from the second sample. The same areas were then exposed to portable NMR, and the sequences used as following: the stimulated echo sequence for diffusion (D), the Carr-Purcell-Meiboom-Gill (CPMG) sequence for T-2, and saturation recovery sequence for T-1. The correlations between the grayscale values and NMR techniques were strongly correlated. The Pearson correlation coefficient, R, of T-1 (%) versus grayscale value, D (%) versus grayscale value, and T-2 (%) versus grayscale value, was 0.91, 0.91, and 0.93, respectively. Furthermore, the relative water content of the breast slices based on T-1, T-2, and diffusion (D) measurements were strongly in agreement with each other. The Pearson correlation coefficient, R, of D (%) versus T-1 (%), D (%) versus T-2 (%), and T-1 (%) versus T-2 (%), was 0.984, 0.966, and 0.9868, respectively. The three pulse sequences can be employed in a portable NMR device to deliver continuous quantitative measurements of MD in breast tissue samples. As a result, the method demonstrated to be acceptable for determining the distribution of MDs among breast tissue samples without the need for additional qualitative analysis. (C) 2021 The Author(s). Published by Elsevier B.V. on behalf of King Saud University.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据