4.6 Article

Design and Optimization of a Novel SAW Gyroscope Structure Based on Amplitude Modulation with 1-D Phononic Crystals

期刊

MICROMACHINES
卷 12, 期 12, 页码 -

出版社

MDPI
DOI: 10.3390/mi12121485

关键词

surface acoustic wave gyroscope; phononic crystals; traveling wave; amplitude modulation; theoretical modeling and simulation design

向作者/读者索取更多资源

A novel surface acoustic traveling wave gyroscope based on amplitude modulation using one-dimensional phononic crystals is proposed to achieve both high-sensitivity and simple signal processing. The theoretical analysis and finite element method design research demonstrate the higher sensitivity and wider linear range of the proposed gyroscope under specific structure.
Surface acoustic wave gyroscopes (SAWGs), as a kind of all-solid-state micro-electro-mechanical system (MEMS) gyroscopes, can work normally under extremely high-impact environmental conditions. Among the current SAWGs, amplitude-modulated gyroscopes (AMGs) are all based on the same gyro effect, which was proved weak, and their sensitivity and intensity of the output are both lower than frequency-modulated gyroscopes (FMGs). However, because FMGs need to process a series of frequency signals, their signal processing and circuits are far less straightforward and simple than AMGs. In order to own both high-sensitivity and simple signal processing, a novel surface acoustic traveling wave gyroscope based on amplitude modulation is proposed, using one-dimensional phononic crystals (PCs) in this paper. In view of its specific structure, the proposed gyroscope consists of a surface acoustic wave oscillator and a surface acoustic wave delay line within a one-dimensional phononic crystal with a high-Q defect mode. In this paper, the working principle is analyzed theoretically through the partial wave method (PWM), and the gyroscopes with different numbers of PCs are also designed and studied by using the finite element method (FEM) and multiphysics simulation. The research results demonstrate that under a 1 V oscillator voltage output, the higher sensitivity of -23.1 mV center dot(rad/s)(-1) in the linear range from -8 rad/s to 8 rad/s is reached when the gyro with three PC walls, and the wider linear range from -15 rad/s to 17.5 rad/s with the sensitivity of -6.7 mV center dot(rad/s)(-1) with only one PC wall. Compared with the existing AMGs using metal dots to enhance the gyro effect, the sensitivity of the proposed gyro is increased by 15 to 112 times, and the linear range is increased by 4.6 to 186 times, even without the enhancement of the metal dots.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据