4.6 Article

Modular 3D In Vitro Artery-Mimicking Multichannel System for Recapitulating Vascular Stenosis and Inflammation

期刊

MICROMACHINES
卷 12, 期 12, 页码 -

出版社

MDPI
DOI: 10.3390/mi12121528

关键词

3D printing; in vitro artery-mimicking model; inflammation; modular microfluidic system; vascular stenosis

资金

  1. National Research Foundation of Korea (NRF) - Korean government (MSIT) [NRF-2019R1A2B5B03070494]

向作者/读者索取更多资源

The study presents a modular multichannel system that mimics the stenosis and inflammation processes in arteries and studies the physical and chemical effects on biomimetic artery models. Through modularization, the system enables reproducible and stable operations, with the flexibility to replace modules for different analytical purposes. This system has the potential to be utilized for comprehensive research on vascular diseases such as atherosclerosis and thrombosis through tunable channel geometry and microfluidic interfacing.
Inflammation and the immune response in atherosclerosis are complex processes involving local hemodynamics, the interaction of dysfunctional cells, and various pathological environments. Here, a modular multichannel system that mimics the human artery to demonstrate stenosis and inflammation and to study physical and chemical effects on biomimetic artery models is presented. Smooth muscle cells and endothelial cells were cocultured in the wrinkled surface in vivo-like circular channels to recapitulate the artery. An artery-mimicking multichannel module comprised four channels for the fabrication of coculture models and assigned various conditions for analysis to each model simultaneously. The manipulation became reproducible and stable through modularization, and each module could be replaced according to analytical purposes. A chamber module for culture was replaced with a microfluidic concentration gradient generator (CGG) module to achieve the cellular state of inflamed lesions by providing tumor necrosis factor (TNF)-alpha, in addition to the stenosis structure by tuning the channel geometry. Different TNF-alpha doses were administered in each channel by the CGG module to create functional inflammation models under various conditions. Through the tunable channel geometry and the microfluidic interfacing, this system has the potential to be used for further comprehensive research on vascular diseases such as atherosclerosis and thrombosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据