4.6 Article

A Photogrammetric Method for the Measurement of Three-Dimensional Cervical Range of Motion

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JBHI.2021.3089254

关键词

Cervical range of motion; goniometer; Hough transform; photogrammetry; Radon transform

资金

  1. National Key Research and Development Program [2017YFB1302102]
  2. National Natural Science Foundation of China [61973194]
  3. Fundamental Research Fund of Shandong University [2018JC031]
  4. Major Scientific and Technological Innovation Project of Shandong Province [2019JZZY010427]
  5. Shenzhen Fundamental Research and Discipline Layout project [JCYJ20190806155616366]

向作者/读者索取更多资源

Cervical spondylosis is a common disease in today's society. This study developed a novel photogrammetric method to assess the three-dimensional cervical range of motion (CROM). The method demonstrated excellent reliability and high agreement with the traditional goniometer-based method. Additionally, a cervical motion curve concept was proposed to represent the movement track of the neck and reflect cervical health status.
Cervical spondylosis has gradually become a high-incidence disease in today's society. The cervical range of motion (CROM) is widely used as the evaluation criterion of cervical status, whereas the existing methods of CROM measuring are not humanized enough. Consequently, the purpose of this study was to develop a novel photogrammetric method to assess three-dimensional CROM. Three smartphone cameras were controlled to simultaneously capture three-direction photographs of the subject wearing the special designed device with three mark lines. The obtained photographs were uploaded to a PC and the mark lines in each photograph were extracted by utilizing both the Radon transform and the Hough transform. By calculating and combining the tilt angles of three mark lines, the CROM of the subject was indirectly determined. The performance of our method was compared with the goniometer-based method: the interinstrument reliability was excellent for all six cervical movements with intraclass correlation coefficients >0.99; the degree of agreement between the two methods was high with Pearson's coefficients >0.98; and the Bland-Altman plots also revealed the validity of our method. Moreover, the concept of a cervical motion curve was put forward to describe the movement track of the neck in order to reflect the cervical health status. The proposed approach is feasible, automatic and convenient for the measurement of CROM and the generated cervical motion curve can intuitively exhibit the trajectory of the neck. This technique that can easily acquire the biomedical information of the cervical spine has tremendous potential in the diagnosis, healthcare and wellness management of the neck.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据