4.7 Article

A Meta-Analysis of Wearable Contact Lenses for Medical Applications: Role of Electrospun Fiber for Drug Delivery

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Review Chemistry, Multidisciplinary

Ophthalmic Sensors and Drug Delivery

Antonysamy Dennyson Savariraj et al.

Summary: Advancements in multifunctional materials have enabled contact lenses to serve as wearable devices for monitoring physiological parameters and delivering drugs. Contact lens sensors can non-invasively measure various parameters and enable self-examination at home. Additionally, drug-laden contact lenses have emerged as platforms for extended drug delivery in the eye.

ACS SENSORS (2021)

Review Automation & Control Systems

Smart Contact Lenses for Biosensing Applications

Xin Ma et al.

Summary: Smart contact lenses with multifunctional biosensing capabilities and highly integrated performance provide a great platform for eye disease diagnosis and drug delivery. Biosensors in contact lenses measure key metabolites, and drug delivery through contact lenses can be beneficial.

ADVANCED INTELLIGENT SYSTEMS (2021)

Article Materials Science, Multidisciplinary

Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors

Shiqi Guo et al.

Summary: Smart contact lenses with a flexible fabrication method and ultrathin MoS2 transistor-based serpentine mesh sensor system have been developed, integrating photodetector, glucose sensor, and temperature sensor for high sensitivity and biocompatibility, showing promise for healthcare and medical applications.

MATTER (2021)

Article Ophthalmology

Non-invasive Intraocular pressure monitoring with contact lens

Angelica Campigotto et al.

BRITISH JOURNAL OF OPHTHALMOLOGY (2020)

Article Materials Science, Multidisciplinary

Recent Advances in Smart Contact Lenses

Joohee Kim et al.

ADVANCED MATERIALS TECHNOLOGIES (2020)

Article Pharmacology & Pharmacy

Electrospun nanofibers - A promising solid in-situ gelling alternative for ocular drug delivery

Benedikt Goettel et al.

EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS (2020)

Article Chemistry, Medicinal

Novel Polyvinyl Pyrrolidone–Loaded Olopatadine HCl–Laden Doughnut Contact Lens to Treat Allergic Conjunctivitis

Yushun Xue et al.

JOURNAL OF PHARMACEUTICAL SCIENCES (2020)

Article Nanoscience & Nanotechnology

Highly Transparent and Sensitive Graphene Sensors for Continuous and Non-invasive Intraocular Pressure Monitoring

Jiandong Xu et al.

ACS APPLIED MATERIALS & INTERFACES (2020)

Article Ophthalmology

Stimulus-Responsive Contact Lens for IOP Measurement or Temperature-Triggered Drug Release

Se-Hee Lee et al.

TRANSLATIONAL VISION SCIENCE & TECHNOLOGY (2020)

Article Multidisciplinary Sciences

Wireless smart contact lens for diabetic diagnosis and therapy

Do Hee Keum et al.

SCIENCE ADVANCES (2020)

Review Materials Science, Multidisciplinary

Ophthalmic Wearable Devices for Color Blindness Management

Ahmed E. Salih et al.

ADVANCED MATERIALS TECHNOLOGIES (2020)

Article Materials Science, Biomaterials

Multiple drug delivery from the drug-implants-laden silicone contact lens: Addressing the issue of burst drug release

Ankita R. Desai et al.

MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS (2020)

Article Biochemical Research Methods

Integration of paper microfluidic sensors into contact lenses for tear fluid analysis

Rosalia Moreddu et al.

LAB ON A CHIP (2020)

Article Nanoscience & Nanotechnology

Magnetic micropump embedded in contact lens for on-demand drug delivery

Cong Wang et al.

MICRO AND NANO SYSTEMS LETTERS (2020)

Article Biochemical Research Methods

Photonic crystal-based smart contact lens for continuous intraocular pressure monitoring

Bohee Maeng et al.

LAB ON A CHIP (2020)

Article Chemistry, Analytical

Non-invasive detection of glucose via a solution-gated graphene transistor

Mingyu Ma et al.

ANALYST (2020)

Review Biotechnology & Applied Microbiology

Wearable biosensors for healthcare monitoring

Jayoung Kim et al.

NATURE BIOTECHNOLOGY (2019)

Article Biophysics

Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose

Juliane R. Sempionatto et al.

BIOSENSORS & BIOELECTRONICS (2019)

Article Engineering, Electrical & Electronic

A Multifunctional Smart Soft Contact Lens Device Enabled by Nanopore Thin Film for Glaucoma Diagnostics and In Situ Drug Delivery

Chao Song et al.

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS (2019)

Article Engineering, Biomedical

Thermo-sensitive nanogel-laden bicontinuous microemulsion drug-eluting contact lenses

Se-Hee Lee et al.

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS (2019)

Article Chemistry, Medicinal

Engineering and Development of Chitosan-Based Nanocoatings for Ocular Contact Lenses

Prina Mehta et al.

JOURNAL OF PHARMACEUTICAL SCIENCES (2019)

Article Biochemistry & Molecular Biology

A guide to deep learning in healthcare

Andre Esteva et al.

NATURE MEDICINE (2019)

Article Chemistry, Multidisciplinary

A contact lens promising for non-invasive continuous intraocular pressure monitoring

Yu Pang et al.

RSC ADVANCES (2019)

Article Materials Science, Multidisciplinary

Assessing theex vivopermeation behaviour of functionalised contact lens coatings engineered using an electrohydrodynamic technique

Prina Mehta et al.

JOURNAL OF PHYSICS-MATERIALS (2019)

Article Chemistry, Multidisciplinary

Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones

Mohamed Elsherif et al.

ACS NANO (2018)

Article Multidisciplinary Sciences

Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays

Jihun Park et al.

SCIENCE ADVANCES (2018)

Article Nanoscience & Nanotechnology

Self-Reporting Colorimetric Analysis of Drug Release by Molecular Imprinted Structural Color Contact Lens

Jingzhe Deng et al.

ACS APPLIED MATERIALS & INTERFACES (2018)

Article Biochemical Research Methods

Ultra-sensitive microfluidic wearable strain sensor for intraocular pressure monitoring

Sevda Agaoglu et al.

LAB ON A CHIP (2018)

Article Optics

Do EnChroma glasses improve color vision for colorblind subjects?

L. Gomez-Robledo et al.

OPTICS EXPRESS (2018)

Article Pharmacology & Pharmacy

Electrically atomised formulations of timolol maleate for direct and on-demand ocular lens coatings

Prina Mehta et al.

EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS (2017)

Article Ophthalmology

Extended Ciprofloxacin Release Using Vitamin E Diffusion Barrier From Commercial Silicone-Based Soft Contact Lenses

Maryam Shayani Rad et al.

EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE (2017)

Article Multidisciplinary Sciences

Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

Joohee Kim et al.

NATURE COMMUNICATIONS (2017)

Article Materials Science, Biomaterials

Electrospun organic-inorganic nanohybrids as sustained release drug delivery systems

Yanshan Gao et al.

JOURNAL OF MATERIALS CHEMISTRY B (2017)

Article Multidisciplinary Sciences

Preparation of active 3D film patches via aligned fiber electrohydrodynamic (EHD) printing

Jun-Chuan Wang et al.

SCIENTIFIC REPORTS (2017)

Article Endocrinology & Metabolism

IDF Diabetes Atlas: Global estimates for the prevalence of diabetes for 2015 and 2040

K. Ogurtsova et al.

DIABETES RESEARCH AND CLINICAL PRACTICE (2017)

Article Dentistry, Oral Surgery & Medicine

Human chemerin correlation in gingival crevicular fluid and tear fluid as markers of inflammation in chronic periodontitis and type-2 diabetes mellitus

Kaushik Patnaik et al.

JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY (2017)

Article Chemistry, Multidisciplinary

A Hydrogel-Based Hybrid Theranostic Contact Lens for Fungal Keratitis

Jian-Fei Huang et al.

ACS NANO (2016)

Article Engineering, Biomedical

Prevention of lung cancer recurrence using cisplatin-loaded superhydrophobic nanofiber meshes

Jonah A. Kaplan et al.

BIOMATERIALS (2016)

Article Endocrinology & Metabolism

Risk of Cause-Specific Death in Individuals With Diabetes: A Competing Risks Analysis

Jose Miguel Baena-Diez et al.

DIABETES CARE (2016)

Article Engineering, Electrical & Electronic

Optical Based Noninvasive Glucose Monitoring Sensor Prototype

Shyqyri Haxha et al.

IEEE PHOTONICS JOURNAL (2016)

Review Instruments & Instrumentation

A comprehensive insight on ocular pharmacokinetics

Vibhuti Agrahari et al.

DRUG DELIVERY AND TRANSLATIONAL RESEARCH (2016)

Article Biochemical Research Methods

Single unit filter-aided method for fast proteomic analysis of tear fluid

Cecilie Aass et al.

ANALYTICAL BIOCHEMISTRY (2015)

Article Electrochemistry

A Miniature Graphene-based Biosensor for Intracellular Glucose Measurements

Kamran ul Hasan et al.

ELECTROCHIMICA ACTA (2015)

Review Chemistry, Medicinal

Therapeutic contact lenses: a patent review

Phillip Dixon et al.

EXPERT OPINION ON THERAPEUTIC PATENTS (2015)

Review Chemistry, Multidisciplinary

Sustained drug release by contact lenses for glaucoma treatment-A review

I. M. Carvalho et al.

JOURNAL OF CONTROLLED RELEASE (2015)

Article Ophthalmology

The Most Common Barriers to Glaucoma Medication Adherence A Cross-Sectional Survey

Paula Anne Newman-Casey et al.

OPHTHALMOLOGY (2015)

Article Mathematical & Computational Biology

Color Processing for Color-Blind Individuals Using Smart Glasses

Jacek Ruminski

JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS (2015)

Review Engineering, Biomedical

Contact Lens Sensors in Ocular Diagnostics

Nicholas M. Farandos et al.

ADVANCED HEALTHCARE MATERIALS (2015)

Article Ophthalmology

Proteomics Differentiate Between Thyroid-Associated Orbitopathy and Dry Eye Syndrome

Nina Matheis et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2015)

Review Ophthalmology

Noninvasive intraocular pressure monitoring: current insights

Stefan De Smedt

CLINICAL OPHTHALMOLOGY (2015)

Article Materials Science, Biomaterials

Silk fibroin nanoparticles prepared by electrospray as controlled release carriers of cisplatin

Jing Qu et al.

MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS (2014)

Article Biochemistry & Molecular Biology

An implantable microfluidic device for self-monitoring of intraocular pressure

Ismail E. Araci et al.

NATURE MEDICINE (2014)

Article Engineering, Biomedical

Soft wearable contact lens sensor for continuous intraocular pressure monitoring

Guo-Zhen Chen et al.

MEDICAL ENGINEERING & PHYSICS (2014)

Article Chemistry, Multidisciplinary

Polymer-controlled core-shell nanoparticles: a novel strategy for sequential drug release

Yang Cao et al.

RSC ADVANCES (2014)

Article Engineering, Biomedical

A Minimally Invasive Implantable Wireless Pressure Sensor for Continuous IOP Monitoring

Girish Chitnis et al.

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2013)

Article Chemistry, Multidisciplinary

Glaucoma therapy by extended release of timolol from nanoparticle loaded silicone-hydrogel contact lenses

Hyun Jung Jung et al.

JOURNAL OF CONTROLLED RELEASE (2013)

Article Engineering, Electrical & Electronic

Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring

Guo-Zhen Chen et al.

SENSORS AND ACTUATORS A-PHYSICAL (2013)

Article Ophthalmology

Tear fluid proteomics multimarkers for diabetic retinopathy screening

Zsolt Torok et al.

BMC OPHTHALMOLOGY (2013)

Article Public, Environmental & Occupational Health

Cystatin C and lactoferrin concentrations in biological fluids as possible prognostic factors in eye tumor development

Mariya A. Dikovskaya et al.

INTERNATIONAL JOURNAL OF CIRCUMPOLAR HEALTH (2013)

Article Ophthalmology

Drug Delivery by Contact Lens in Spontaneously Glaucomatous Dogs

Cheng-Chun Peng et al.

CURRENT EYE RESEARCH (2012)

Review Ophthalmology

Advances in Ocular Drug Delivery

Mutasem Rawas-Qalaji et al.

CURRENT EYE RESEARCH (2012)

Article Engineering, Electrical & Electronic

A 3-μW CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring

Yu-Te Liao et al.

IEEE JOURNAL OF SOLID-STATE CIRCUITS (2012)

Article Chemistry, Multidisciplinary

Extended drug delivery by contact lenses for glaucoma therapy

Cheng-Chun Peng et al.

JOURNAL OF CONTROLLED RELEASE (2012)

Article Multidisciplinary Sciences

Lacrimal Proline Rich 4 (LPRR4) Protein in the Tear Fluid Is a Potential Biomarker of Dry Eye Syndrome

Saijyothi Venkata Aluru et al.

PLOS ONE (2012)

Article Biophysics

A contact lens with embedded sensor for monitoring tear glucose level

Huanfen Yao et al.

BIOSENSORS & BIOELECTRONICS (2011)

Article Endocrinology & Metabolism

IDF Diabetes Atlas: Global estimates of the prevalence of diabetes for 2011 and 2030

David R. Whiting et al.

DIABETES RESEARCH AND CLINICAL PRACTICE (2011)

Article Engineering, Electrical & Electronic

A single-pixel wireless contact lens display

A. R. Lingley et al.

JOURNAL OF MICROMECHANICS AND MICROENGINEERING (2011)

Article Engineering, Electrical & Electronic

Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film

Vladimir Laukhin et al.

SENSORS AND ACTUATORS A-PHYSICAL (2011)

Editorial Material Endocrinology & Metabolism

Finger-Stick Glucose Monitoring Issues of accuracy and specificity

Leann Olansky et al.

DIABETES CARE (2010)

Article Endocrinology & Metabolism

Global estimates of the prevalence of diabetes for 2010 and 2030

J. E. Shaw et al.

DIABETES RESEARCH AND CLINICAL PRACTICE (2010)

Review Ophthalmology

Colour vision deficiency

M. P. Simunovic

Article Engineering, Biomedical

A Fully Integrated RF-Powered Contact Lens With a Single Element Display

Jagdish Pandey et al.

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS (2010)

Article Ophthalmology

Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement

Michael D. Twa et al.

JOURNAL OF GLAUCOMA (2010)

Article Ophthalmology

Analysis of tear fluid proteins in insulin-dependent diabetes mellitus

Thorsten R. Stolwijk et al.

ACTA OPHTHALMOLOGICA (2009)

Review Pharmacology & Pharmacy

Topical ocular delivery of NSAIDs

Munish Ahuja et al.

AAPS JOURNAL (2008)

Article Biophysics

Effect of cornea material stiffness on measured intraocular pressure

T. H. Kwon et al.

JOURNAL OF BIOMECHANICS (2008)

Article Ophthalmology

Effect of central corneal thickness on Goldmann applanation tonometry measures - a different result with different pachymeters

Michael J. Doughty et al.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2007)

Review Chemistry, Multidisciplinary

Electrospinning: A fascinating method for the preparation of ultrathin fibres

Andreas Greiner et al.

ANGEWANDTE CHEMIE-INTERNATIONAL EDITION (2007)

Article Ophthalmology

Visual acuity and X-linked color blindness

H Jägle et al.

GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY (2006)

Article Biotechnology & Applied Microbiology

Identification of 491 proteins in the tear fluid proteome reveals a large number of proteases and protease inhibitors

Gustavo A. de Souza et al.

GENOME BIOLOGY (2006)

Article Biochemical Research Methods

Characterization of human tear proteome using multiple proteomic analysis techniques

N Li et al.

JOURNAL OF PROTEOME RESEARCH (2005)

Review Pharmacology & Pharmacy

Colloidal carriers for ophthalmic drug delivery

RM Mainardes et al.

CURRENT DRUG TARGETS (2005)

Article Ophthalmology

First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens

M Leonardi et al.

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE (2004)

Review Chemistry, Multidisciplinary

Electrospinning of nanofibers: Reinventing the wheel?

D Li et al.

ADVANCED MATERIALS (2004)

Article Endocrinology & Metabolism

Global prevalence of diabetes - Estimates for the year 2000 and projections for 2030

S Wild et al.

DIABETES CARE (2004)

Review Biotechnology & Applied Microbiology

Development of novel tissue engineering scaffolds via electrospinning

LS Nair et al.

EXPERT OPINION ON BIOLOGICAL THERAPY (2004)

Article Chemistry, Multidisciplinary

Electrospinning of polymeric and ceramic nanofibers as uniaxially aligned arrays

D Li et al.

NANO LETTERS (2003)

Review Chemistry, Physical

Polymer nanofibers assembled by electrospinning

A Frenot et al.

CURRENT OPINION IN COLLOID & INTERFACE SCIENCE (2003)

Article Pharmacology & Pharmacy

Biopharmaceutical considerations in topical ocular drug delivery

NM Davies

CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY (2000)