4.3 Article

Evaluation of an Ozone Chamber as a Routine Method to Decontaminate Firefighters' PPE

出版社

MDPI
DOI: 10.3390/ijerph182010587

关键词

ozone; ozonolysis; firefighters; work safety; personal protective clothes (PPC); decontamination; polycyclic aromatic hydrocarbons (PAH)

资金

  1. Madrid Fire Department [83 LOU, 148/2018]
  2. CAPES/BRAZIL [3509/2014]
  3. University of Alcala

向作者/读者索取更多资源

This study evaluated the efficiency of using an ozone chamber to clean firefighters' PPE, revealing the risks associated with the presence of remaining PAH and oxygenated-PAH compounds after treatment. Despite some chemical degradation observed, the new compounds might be equally or more toxic than the initial PAH, highlighting the limitations of ozone chambers as a sole decontamination method for firefighters.
Ozone chambers have emerged as an alternative method to decontaminate firefighters' Personal Protective Equipment (PPE) from toxic fire residues. This work evaluated the efficiency of using an ozone chamber to clean firefighters' PPE. This was achieved by studying the degradation of pyrene and 9-methylanthracene polycyclic aromatic hydrocarbons (PAHs). The following experiments were performed: (i) insufflating ozone into PAH solutions (homogeneous setup), and (ii) exposing pieces of PPE impregnated with the PAHs to an ozone atmosphere for up to one hour (heterogeneous setup). The ozonolysis products were assessed by Fourier Transform Infrared Spectroscopy (FTIR), Thin-Layer Chromatography (TLC), and Mass Spectrometry (MS) analysis. In the homogeneous experiments, compounds of a higher molecular weight were produced due to the incorporation of oxygen into the PAH structures. Some of these new compounds included 4-oxapyren-5-one (m/z 220) and phenanthrene-4,5-dicarboxaldehyde (m/z 234) from pyrene; or 9-anthracenecarboxaldehyde (m/z 207) and hydroxy-9,10-anthracenedione (m/z 225) from 9-methylanthracene. In the heterogeneous experiments, a lower oxidation was revealed, since no byproducts were detected using FTIR and TLC, but only using MS. However, in both experiments, significant amounts of the original PAHs were still present even after one hour of ozone treatment. Thus, although some partial chemical degradation was observed, the remaining PAH and the new oxygenated-PAH compounds (equally or more toxic than the initial molecules) alerted us of the risks to firefighters' health when using an ozone chamber as a unique decontamination method. These results do not prove the ozone-advertised efficiency of the ozone chambers for decontaminating (degrading the toxic combustion residues into innocuous compounds) firefighters' PPE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据