4.4 Article

Analysis of Sintered Wicked Heat Pipes for Space-Constrained Multiple Component Cooling

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TCPMT.2021.3121497

关键词

Bending; effective thermal conductivity; electronics cooling; heat pipe; multiple heat sources (MHSs)

资金

  1. Science Foundation Ireland (SFI) [13/RC/2077]
  2. European Regional Development Fund through the SFI Research Centres Program

向作者/读者索取更多资源

The study investigated the impact of different heat pipe configurations on thermal performance, finding that the combination of MHS, bend angle, and bend location has unique effects on fluid transport mechanisms inside the heat pipe, leading to changes in thermal performance across different configurations.
Contemporary electronic cooling applications can feature complex heat pipe configurations with multiple heat sources (MHSs) and one or more bends in various locations to meet physical constraints. It is typically understood that implementing a bend or adding MHS to a heat pipe that was tested for a straight single heat source (SHS) heat pipe can degrade thermal performance. However, the severity of combining the two phenomena and the effects of changing the location of a bend in an MHS heat pipe are unknown. In this context, this study presents an experimental investigation of the thermal performance of four configurations for 400-mm-long, 6-mm-diameter, cylindrical copper sintered heat pipes, where small, heated copper saddles are configured as evaporators: a pipe with an SHS, a pipe with MHS, an MHS heat pipe with an increasing bend angle from 0 degrees to 90 degrees, and an MHS heat pipe where the location of a 90 degrees bend is moved along the axis. The results demonstrate that a bent MHS heat pipe does not act in a similar manner to a conventional SHS heat pipe or a straight MHS heat pipe. It was found that the thermal resistance increases by up to 65% when the configuration is changed from SHS to MHS, and the bend angle is found to increase the resistance further by 15%-65%. For the MHS cases, bend location induces resistance increases of degrees 5%-18%. Furthermore, the optimum bend location for the MHS case is found to be adjacent to the middle evaporator (of five), for cases in which the heat load is evenly distributed before and after the bend. The results suggest that the combination of MHS, bend angle, and bend location has unique effects on the fluid transport mechanisms inside the heat pipe and, thus, thermal performance changes between bend location configurations. Therefore, it is concluded that a bent MHS heat pipe configuration should not be designed on the basis of the thermal characteristics for straight SHS heat pipes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据