4.4 Article

Development of a europium nanoparticles lateral flow immunoassay for NGAL detection in urine and diagnosis of acute kidney injury

期刊

BMC NEPHROLOGY
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12882-021-02493-w

关键词

neutrophil gelatinase-associated lipocalin (NGAL); monoclonal antibody; lateral flow immunoassay; acute kidney injury (AKI)

资金

  1. `Research and Development of Industrial Technology' Program of Jilin Province, PR China [20180623045TC, 20170204005YY]
  2. National Natural Science Foundation of China [21827812]
  3. National Training Program of Innovation and Entrepreneurship for Undergraduates [201913706017, 202013706002]

向作者/读者索取更多资源

A rapid and accurate method for detecting NGAL in urine specimens has been established based on europium nanoparticles, providing important evidence for the early diagnosis of acute kidney injury.
Background AKI is related to severe adverse outcomes and mortality with Coronavirus Disease 2019 (COVID-19) patients, that early diagnosed and intervened is imperative. Neutrophil gelatinase-associated lipocalin (NGAL) is one of the most promising biomarkers for detection of acute kidney injury (AKI), but current detection methods are inadequacy, so more rapid, convenient and accuracy methods are needed to detect NGAL for early diagnosis of AKI. Herein, we established a rapid, reliable and accuracy lateral flow immunoassay (LFIA) based on europium nanoparticles (EU-NPS) for the detection of NGAL in human urine specimens. Methods A double-antibody sandwich immunofluorescent assay using europium doped nanoparticles was employed and the NGAL monoclonal antibodies (MAbs) conjugate as labels were generated by optimizing electric fusion parameters. Eighty-three urine samples were used to evaluate the clinical application efficiency of this method. Results The quantitative detection range of NGAL in AKI was 1-3000 ng/mL, and the detection sensitization was 0.36 ng/mL. The coefficient of variation (CV) of intra-assay and inter-assay were 2.57-4.98 % and 4.11-7.83 %, respectively. Meanwhile, the correlation coefficient between europium nanoparticles-based lateral fluorescence immunoassays (EU-NPS-LFIA) and ARCHITECT analyzer was significant (R-2 = 0.9829, n = 83, p < 0.01). Conclusions Thus, a faster and easier operation quantitative assay of NGAL for AKI has been established, which is very important and meaningful to diagnose the early AKI, suggesting that the assay can provide an early warning of final outcome of disease.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据