4.7 Article

Nanosecond resolution photography system for laser-induced cavitation based on PIV dual-head laser and industrial camera

期刊

ULTRASONICS SONOCHEMISTRY
卷 78, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultsonch.2021.105733

关键词

Photography system; Temporal resolution; Nanosecond; Laser; Cavitation

资金

  1. National Natural Science Foundation of China [51836010, 51809268]
  2. National Training Program of Innovation and Entrepreneurship for Undergraduates of China [202010019053]
  3. Joint Fund of State key Lab of Hydroscience and Institute of Internet of Waters Tsinghua-Ningxia Yinchuan [sklhse-2020-Iow06]

向作者/读者索取更多资源

The study focuses on the detailed analysis of the initial and collapse processes of laser-induced cavitation, using a nanosecond resolution photography system based on PIV dual-head laser and conventional industrial camera. The experimental results demonstrate the reliability of the system and reveal the asymmetric evolution of laser-induced cavitation bubbles.
The detailed study of the initial and collapse processes of the laser-induced cavitation requires nanosecond resolution (both nanoseconds exposure and nanoseconds interframe time) of the photography measurement system. The high-speed video cameras are difficult to achieve nanoseconds interval time. The framing and streak cameras are able to reach the nanosecond resolution, but their complex technology and expensive prices make them far from being commercially available. The present study builds a nanosecond resolution photography system based on PIV dual-head laser and conventional industrial camera. The exposure time of the photography system is controlled by the laser pulse width, which is 5 ns. The two heads of the PIV laser are operated independently thus the smallest time interval between two laser pulses can be set to less than 10 ns. A double-pulse per-exposure imaging technique is used to record the information from two laser pulses on single frame on a lowspeed industrial camera. The nanosecond resolution photography system was applied to the laser-induced cavitation experiments to verify the reliability of the measurement results. The measurement of the shock wave velocity demonstrates the ability of the system to capture ultrafast phenomena, which reduces from 3611 m/s to approximately 1483 m/s within 400 ns. The experimental results also reveal the asymmetric evolution of laser-induced cavitation bubbles. The major axis of the ellipsoidal bubble has twice reversals along the laser propagation and perpendicular direction from the laser-induced breakdown to the first collapse.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据