4.4 Article

Reducing electron beam damage through alternative STEM scanning strategies, Part I: Experimental findings

期刊

ULTRAMICROSCOPY
卷 232, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultramic.2021.113398

关键词

Scanning transmission electron microscopy; Electron beam damage; Scanning strategies

资金

  1. FWO [G093417N, G042920N]
  2. European Union [823717 ESTEEM3]
  3. Hercules fund from the Flemish Government
  4. GOA project Solarpaint of the University of Antwerp

向作者/读者索取更多资源

Highly energetic electrons in a transmission electron microscope can damage sample structures, especially in zeolites, organics, and biological materials. Investigating the role of different scan patterns in damage behavior showed significant differences in beam damage, challenging the community to rethink beam damage in (S)TEM experiments.
The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据