4.7 Article

First-order derivative synchronous spectrofluorimetric determination of two antihypertensive drugs, metolazone and valsartan, in pharmaceutical and biological matrices

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.saa.2021.120591

关键词

Metolazone; Valsartan; Synchronous spectrofluorimetry; Mathematical derivatization; Pharmaceutical dosage; Biological matrices

向作者/读者索取更多资源

In this study, a facile, rapid, and sensitive spectrofluorimetric method was developed for simultaneous analysis of two antihypertensive drugs, MTZ and VST. The method combined derivative and synchronous spectrofluorometry to overcome the strong overlap between their fluorescence spectra. By optimizing the solvent and parameters, the method achieved high sensitivity and selectivity. The validity of the proposed method was confirmed for quality control work in pharmaceutical dosage and biological matrices.
In this study, a facile, rapid, and sensitive spectrofluorimetric method was evolved to analyse two antihypertensive drugs, namely, metolazone (MTZ) and valsartan (VST), in pharmaceutical and biological matrices. Both analytes exhibited intrinsic fluorescence activities which were significantly affected by environmental factors such as pH and solvent systems. However, simultaneous determination of MTZ and VST by conventional spectrofluorometry cannot be achieved simply because of the strong overlap between their fluorescence spectra. Thus, a combination of derivative and synchronous spectrofluorometry was conducted to overcome this dilemma. The proposed method relies on measurement of the first-order derivative of synchronous fluorescence intensity of the studied drugs at Delta lambda = 160 nm using 0.1 M acetic acid as the optimum solvent. The amplitudes of the first derivative synchronous fluorescence spectra of MTZ and VST were recorded at 236.0 nm (zero-crossing point of VST) and at 262.8 nm (zerocrossing point of MTZ) for simultaneous analysis of MTZ and VST, respectively. The fluorescent method was optimized efficiently to get the maximum selectivity and sensitivity by investigating different solvents, different buffer pHs, and different surfactants. The highest sensitivity and selectivity were achieved when 0.1 M acetic acid was used as a solvent. The method showed a linear concentration range of 10.0-100.0 ng mL(-1) and a limit of detection of <3.0 ng mL(-1) for each analyte. Statistical data analysis confirmed that no significant difference between the proposed spectrofluorometric method and the reference methods. The validity of the proposed spectrofluorometric method approved its suitability for quality control work. The proposed spectrofluorometric method was applied to assay the studied drugs in pharmaceutical dosage and in biological matrices with acceptable %recoveries and small RSD values. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据