3-Aminophenylboronic acid-mediated aggregation of gold nanoparticles for colorimetric sensing of iohexol in environmental and biological samples

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.saa.2021.120004

关键词

Gold nanoparticles; 3-Aminophenylboronic acid; Colorimetry; Iohexol; Environmental and biological samples

资金

  1. Natural Science Foundation of Hebei Province [B2017402043]
  2. National Natural Science Foundation of China [21705149, 22006086]

向作者/读者索取更多资源

A selective, sensitive, and reliable colorimetric sensing assay based on 3-aminophenylboronic acid (3-APBA) mediated aggregation of gold nanoparticles (AuNPs) was developed for the fast determination of Iohexol (IHO) in environmental and biological samples.
Iohexol (IHO), as one of iodinated X-ray contrast, is often used as not only a chemical marker for tracking wastewater contamination in aquatic environment, but also an ideal glomerular filtration rate marker for explorating kidney disease. To these aims, it is important to establish reliable, fast, and cheap methods to detect IHO in environmental and biological samples. This work describes for the first time the development of a selective, sensitive and reliable colorimetric sensing assay for the fast determination of IHO in environmental and biological samples based on 3-aminophenylboronic acid (3-APBA) mediated aggregation of gold nanoparticles (AuNPs). In this approach, 3-APBA can assemble on the AuNPs surface through electrostatic interaction between its amino groups with the negatively charged citrate stabilizer of AuNPs to form AuNP@3-APBA. Subsequently, the aggregation and visual color change of the assembled AuNP@3APBA are induced by the covalent reaction between boronic acid ligands of 3-APBA and cis-diols of IHO. The developed assay presented a very simple operating procedure and a rapid analysis time of around 10 min. The developed assay also exhibited good selectivity and a low limit of detection (LOD) of 0.005 mM for detecting IHO. Moreover, the developed assay showed comparable accuracy and precision to the high-performance liquid chromatography-diode array detector (HPLC-DAD) method when used for the rapid determination of IHO in river water and human urine samples. The recoveries of IHO at three spiking levels were in the range of 91.5-106.3% with relative standard deviation (RSD) values below 6.39%. (c) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据