4.4 Article

Estimating the Geoelectric Field and Electric Power Transmission Line Voltage During a Geomagnetic Storm in Alberta, Canada Using Measured Magnetotelluric Impedance Data: The Influence of Three-Dimensional Electrical Structures in the Lithosphere

出版社

AMER GEOPHYSICAL UNION
DOI: 10.1029/2021SW002803

关键词

geomagnetic storm; magnetotellurics; geomagnetically induced currents; three-dimensional conductivity

资金

  1. National Science and Engineering Research Council of Canada (NSERC)
  2. Canadian Space Agency

向作者/读者索取更多资源

This study estimates the geoelectric field resulting from a magnetic storm on September 8, 2017 in Alberta and southeastern British Columbia using an array of magnetotelluric (MT) impedance measurements. The geoelectric field derived from the MT impedance data shows partial polarization in southern Alberta, with the highest magnitude in northeastern Alberta. The study also suggests that using the MT impedances results in higher estimated voltages on transmission lines in certain regions compared to using a 1-D conductivity model.
Estimating the effect of geomagnetic disturbances on power grid infrastructure is an important problem since they can induce damaging currents in electric power transmission lines. In this study, an array of magnetotelluric (MT) impedance measurements in Alberta and southeastern British Columbia are used to estimate the geoelectric field resulting from a magnetic storm on September 8, 2017. The resulting geoelectric field is compared to the geoelectric field modeled using the more common method that uses a piecewise-continuous 1-D conductivity model. The 1-D model assumes horizontal layers, which result in orthogonal induced electric fields while the measured MT impedance data can account for fully 3-D conductivity structure. The geoelectric field derived from measured MT impedance data is partially polarized in southern Alberta, and the geoelectric field magnitude is largest in northeastern Alberta where the resistive Canadian Shield outcrops. The induced voltage in the Alberta transmission network is estimated to be similar to 120 V larger in northeastern Alberta when using the measured MT impedances compared to the piecewise-continuous 1-D model. Estimated voltages on transmission lines oriented NW-SE in southern Alberta are 10%-20% larger when using the MT impedances due to the polarized geoelectric field. As shown with forward modeling tests, the polarization is due to a feature in the lower crust (20-30 km depth) called the Southern Alberta British Columbia conductor that is associated with a Proterozoic tectonic suture zone. This forms an important link between ancient tectonic processes and modern-day geoelectric hazards that cannot be modeled with a 1-D analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据