4.7 Article

CRISPR/Cas12a based fluorescence-enhanced lateral flow biosensor for detection of Staphylococcus aureus

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 351, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.130906

关键词

Staphylococcus aureus; Quantum dot; Lateral flow biosensor; CRISPR/Cas12a; Nucleic acid detection

资金

  1. National Key Research and Development Program of China [2019YFC1606300]
  2. Key Research and Development Program of Guangdong Province, China [2018B020205001]
  3. Guangdong Provincial Key Laboratory [2020B121201009]
  4. GDAS' Special Project of Science and Technology Development [2020GDASYL-20200301002]

向作者/读者索取更多资源

The novel CRISPR/Cas12a-based fluorescence enhanced LFB combined with functionalized quantum dots and RAA allows for low-cost, simple, and sensitive detection of Staphylococcus aureus. This method shows high specificity and sensitivity in detecting the target pathogen within a short period of time, making it suitable for onsite testing in food and clinical diagnosis.
Rapid, accurate point-of-care testing (POCT) for pathogenic bacteria detection is the key for avoiding foodborne diseases caused by pathogens or their toxins. The lateral flow biosensor (LFB) based on clustered regularly interspaced short palindromic repeats (CRISPR/Cas) has displayed remarkable potential for pathogen diagnosis. In this study, we report a novel CRISPR/Cas12a-based fluorescence enhanced LFB in conjunction with functionalized quantum dots, combined with recombinase-assisted amplification (RAA), to establish low-cost, simple, and sensitive detection of Staphylococcus aureus, namely CRA-LFB (CRISPR/Cas-recombinase-assisted amplification based LFB). The CRA-LFB assay is characterized by Cas12a-mediated trans-cleavage activation induced by the target DNA to digest biotin-DNA probes, caused no complementarity to the capture probe immobilized on the test (T) line, and resulted in an undetectable T line fluorescence signal on LFB. The naked eye or fluorescence strip reader was used to determine the fluorescence intensity of the T and control lines. The limit of detection (at optimal conditions) was as low as 75 aM of genomic DNA, and 5.4 x 10(2) cfu/mL of S. aureus in pure cultures were detected. Moreover, this CRA-LFB assay can rapidly and accurately detect S. aureus in spiked and natural meat and vegetable samples. The CRA-LFB method yielded high specificity and no interference from other nontargeted bacteria. The results exhibited high-resolution, high-intensity fluorescent signals obtained within 70 min. This bacterial detection platform is simple, low cost, almost equipment-free, and fully qualified for food and clinical diagnosis onsite testing requirements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据