4.7 Article

Total integrated centrifugal genetic analyzer for point-of-care Covid-19 testing with automatic and high-throughput capability

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 353, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.131088

关键词

Covid-19; Centrifugal microfluidics; Loop-mediated isothermal amplification (LAMP); Point-of-care testing; High-throughput

资金

  1. Engineering Research Center of Excellence Program of Korea Ministry of Science, ICT AMP
  2. Future Planning (MSIP) /National Research Foundation of Korea (NRF) [2021R1A5A6002853]
  3. National Research Foundation of Korea (NRF)
  4. Ministry of Science and ICT (MSIT) [2020R1A2C1003960]
  5. Korea Health Technology RAMP
  6. D Project/Korea Health Industry Devel-opment Institute (KHIDI), Ministry of Health AMP
  7. Welfare of South Korea [HI20C0644]
  8. National Research Foundation of Korea [2020R1A2C1003960] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

The proposed prototype portable genetic analyzer can perform RNA extraction, RT-LAMP amplification, and fluorescence detection for ten samples simultaneously in an automatic and high-throughput manner. It utilizes zigzag aliquoting channels and passive valves for sample partitioning and extraction operations.
We propose a prototype portable genetic analyzer, which performs the entire processes including RNA purification, reverse transcription multiplex loop-mediated isothermal amplification (RT-LAMP), and real-time fluorescence detection. Ten units of integrated functional entity were incorporated on a centrifugal disc, so that 10 samples could be analyzed on single device in one run. The 10 aliquoting chambers were connected sidewards by the zigzag aliquoting channel and were linked to the glass filter column outwards via the passive valves for the RNA extraction. The lower sideward capillary pressure of the zigzag aliquoting channel than the outward capillary pressure of the passive values is capable of automatic division of solution into the 10 aliquoting chambers with one injection by a needle. The sequent loading and partitioning of the sample, the washing, and the elution solutions by centrifugal protocols rendered the RT-LAMP cocktails ready for amplification in the three reaction chambers for each sample, in which the RT-LAMP primers targeting orf1ab, N and S genes were dried. After blocking the reaction chambers by wax to prevent evaporation, RT-LAMP reaction proceeded at 63 degrees C, and all the positive fluorescent signals in the three chambers verifies the existence of Covid-19 in the sample. For point-of-care testing (POCT), we constructed a portable workstation that consists of a solution storage, a solution injection system, a spinning motor, and a fluorescence detector. Using the proposed platform, we could perform the Covid-19 molecular diagnostics for 10 samples per run on single device in an automatic and high-throughput manner in 1.5 h.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据