Effect of low-cost transcranial magnetic stimulation navigation on hotspot targeting and motor evoked potential variability in the biceps brachii

期刊

RESTORATIVE NEUROLOGY AND NEUROSCIENCE
卷 39, 期 5, 页码 319-328

出版社

IOS PRESS
DOI: 10.3233/RNN-211207

关键词

Neuronavigation; corticomotor excitability; navigated brain stimulation; voluntary contraction; proximal muscles; upper limb

向作者/读者索取更多资源

The study evaluated the performance of a low-cost navigated TMS approach in improving coil placement consistency and found that it effectively reduced coil orientation errors when tracking motor hotspots, but did not have an impact on MEP amplitudes and variability.
Background: Transcranial magnetic stimulation (TMS) can monitor or modulate brain excitability. However, reliability of TMS outcomes depends on consistent coil placement during stimulation. Neuronavigated TMS systems can address this issue, but their cost limits their use outside of specialist research environments. Objective: The objective was to evaluate the performance of a low-cost navigated TMS approach in improving coil placement consistency and its effect on motor evoked potentials (MEPs) when targeting the biceps brachii at rest and during voluntary contractions. Methods: We implemented a navigated TMS system using a low-cost 3D camera system and open-source software environment programmed using the Unity 3D engine. MEPs were collected from the biceps brachii at rest and during voluntary contractions across two sessions in ten non-disabled individuals. Motor hotspots were recorded and targeted via two conditions: navigated and conventional. Results: The low-cost navigated TMS system reduced coil orientation error (pitch: 1.18 degrees +/- 1.2 degrees, yaw: 1.99 degrees +/- 1.9 degrees, roll: 1.18 degrees +/- 2.2 degrees with navigation, versus pitch: 3.7 degrees +/- 5.7 degrees, yaw: 3.11 degrees +/- 3.1 degrees, roll: 3.8 degrees +/- 9.1 degrees with conventional). The improvement in coil orientation had no effect on MEP amplitudes and variability. Conclusions: The low-cost system is a suitable alternative to expensive systems in tracking the motor hotspot between sessions and quantifying the error in coil placement when delivering TMS. Biceps MEP variability reflects physiological variability across a range of voluntary efforts, that can be captured equally well with navigated or conventional approaches of coil locating.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据