4.5 Article

Fluoranthene removal in aqueous phase by Fe(II) activated sodium percarbonate: mechanisms and degradation pathways

期刊

RESEARCH ON CHEMICAL INTERMEDIATES
卷 48, 期 4, 页码 1645-1663

出版社

SPRINGER
DOI: 10.1007/s11164-021-04624-2

关键词

Sodium percarbonate; Fe(II); Fluoranthene; Reactive oxygen species; Groundwater remediation

资金

  1. National Natural Science Foundation of China [41977164]

向作者/读者索取更多资源

The study investigated the removal performance and degradation mechanisms of fluoranthene in a sodium percarbonate (SPC) activated by Fe(II) system. Results showed that increasing the dosages of SPC and Fe(II) and adjusting the initial solution pH to 5.0 could improve the removal efficiency of FLT in actual groundwater. This study demonstrates the potential of SPC/Fe(II) system in remediating FLT-contaminated groundwater.
In this study, the removal performance and degradation mechanisms of fluoranthene (FLT) in sodium percarbonate (SPC) activated by Fe(II) system were investigated, in which 97.5% removal of FLT could be achieved within 15 min when the concentrations of SPC and Fe(II) were 0.03 and 0.2 mM, respectively. The presence of HO center dot, O-2(-)center dot and O-1(2) was demonstrated by probe tests and electron paramagnetic resonance (EPR) detections, and scavenging experiments further proved that the leading reactive oxygen species (ROSS) contributed to FLT removal in SPC/Fe(II) system was HO center dot. The p-hydroxybenzoic acid analytical result (the reaction product between benzoic acid and HO center dot) found that 66.5% of HO center dot in the system was produced in the first 5 min of the reaction. Several intermediates of FLT were detected by GC-MS and three probable FLT degradation pathways were proposed. The effect of SPC dosage, Fe(II) concentration, initial solution pH and inorganic anions (Cl- and HCO3-) on FLT degradation were assessed. 90.3% FLT was removed in actual groundwater when the dosages of SPC and Fe(II) were 0.15 and 1.0 mM, respectively. This result indicated that FLT removal could be improved by elevating the dosages of SPC and Fe(II) and adjusting the initial solution pH to 5.0, confirming the effective removal of FLT in actual groundwater in SPC/Fe(II) system. Overall, this study demonstrated that SPC/Fe(II) system has broad prospective in the remediation of FLT-contaminated groundwater. [GRAPHICS] .

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据