Evolution of materials for implants in metastatic spine disease till date - Have we found an ideal material?

期刊

RADIOTHERAPY AND ONCOLOGY
卷 163, 期 -, 页码 93-104

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.radonc.2021.08.007

关键词

Spine; Neoplasm metastasis; Implants; Ti6Al4V; Polyether ether ketone; Carbon fiber; Medical imaging; Radiation oncology

向作者/读者索取更多资源

Ti6Al4V is widely used in metastatic spine tumor surgery, but it has issues like stress-shielding and imaging interference. PEEK is a promising alternative due to its low Young's modulus and minimal imaging artifacts, but faces challenges in providing immediate stability postoperatively.
Metastatic Spine Disease (MSD) often requires surgical intervention and instrumentation with spinal implants. Ti6Al4V is widely used in metastatic spine tumor surgery (MSTS) and is the current implant material of choice due to improved biocompatibility, mechanical properties, and compatibility with imaging modalities compared to stainless steel. However, it is still not the ideal implant material due to the following issues. Ti6Al4V implants cause stress-shielding as their Young's modulus (110 gigapascal [GPa]) is higher than cortical bone (17-21 GPa). Ti6Al4V also generates artifacts on CT and MRI, which interfere with the process of postoperative radiotherapy (RT), including treatment planning and delivery. Similarly, charged particle therapy is hindered in the presence of Ti6Al4V. In addition, artifacts on CT and MRI may result in delayed recognition of tumor recurrence and postoperative complications. In comparison, polyether-ether-ketone (PEEK) is a promising alternative. PEEK has a low Young's modulus (3.6 GPa), which results in optimal load-sharing and produces minimal artifacts on imaging with less hinderance on postoperative RT. However, PEEK is bioinert and unable to provide sufficient stability in the immediate postoperative period. This issue may possibly be mitigated by combining PEEK with other materials to form composites or through surface modification, although further research is required in these areas. With the increasing incidence of MSD, it is an opportune time for the development of spinal implants that possess all the ideal material properties for use in MSTS. Our review will explore whether there is a current ideal implant material, available alternatives and whether these require further investigation. (c) 2021 Elsevier B.V. All rights reserved. Radiotherapy and Oncology 163 (2021) 93-104

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据