4.6 Article

Procedure for the selection and evaluation of prefabricated housing buildings for the implementation of green roofs in the context of Urban Heat Island mitigation. The example of Wroclaw, Poland

期刊

PLOS ONE
卷 16, 期 10, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0258641

关键词

-

向作者/读者索取更多资源

The research assessed the potential for greening the roofs of prefabricated apartment blocks in the context of climate effects, proposing a three-stage investigatory procedure. A total of 480 buildings in priority areas were selected for greening, with scenarios defined for extensive and semi-intensive greening. The study highlighted the need for additional strengthening of roof structures to support green roof implementation.
The assessment of the suitability of existing buildings for implementation of green roofs is an important research issue, especially in the context of Urban Heat Island (UHI), the negative impacts of which are locally exacerbated by the global warming. The studies carried out so far have covered a variety of buildings and have taken into account a range of different conditions. Relatively little attention has been paid to the possibilities of greening the roofs of prefabricated apartment blocks from the second half of the 20th century in the context of the potential climate effect. Yet, these buildings are found in many cities around the world, and seem in fact attractive for greening. In view of the above, we proposed a three-stage investigatory procedure to: (I) identify and classify buildings based on the number of floors and the rooftop available area; (II) select buildings by designating priority areas depending on the highest UHI intensity and roof density; (III) analyse the roof load capacity to develop retrofit scenarios. The procedure was applied to prefabricated housing estates built in the 1970s and 1980s in Wroclaw, Poland. The research shows that there are 1962 buildings of different heights and roof area of 722405 m(2), of which 480 buildings with a roof area of 122749.1 m(2) were selected for greening within priority areas. The structure of the studied roofs was not designed to carry additional loads, which requires the application of complementary solutions. Scenario 1 assumes extensive greening provided that the existing ventilated roof is strengthened, scenario 2 -semi-intensive greening, which however requires the conversion of the ventilated roof to a non-ventilated one. The presented procedure can be applied in any other city with prefabricated apartment blocks and available UHI data, and serve to support the decision to implement green roofs to mitigate UHI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据