4.6 Article

A multicenter analytical performance evaluation of a multiplexed immunoarray for the simultaneous measurement of biomarkers of micronutrient deficiency, inflammation and malarial antigenemia

期刊

PLOS ONE
卷 16, 期 11, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0259509

关键词

-

向作者/读者索取更多资源

This study evaluated the performance characteristics and comparability of immunoassay methods for quantifying seven biomarkers across different laboratories. Results showed acceptable precision and linearity in a single lab, with generally good agreement in biomarker results between labs.
A lack of comparative data across laboratories is often a barrier to the uptake and adoption of new technologies. Furthermore, data generated by different immunoassay methods may be incomparable due to a lack of harmonization. In this multicenter study, we describe validation experiments conducted in a single lab and cross-lab comparisons of assay results to assess the performance characteristics of the Q-plex((TM)) 7-plex Human Micronutrient Array (7-plex), an immunoassay that simultaneously quantifies seven biomarkers associated with micronutrient (MN) deficiencies, inflammation and malarial antigenemia using plasma or serum; alpha-1-acid glycoprotein, C-reactive protein, ferritin, histidine-rich protein 2, retinol binding protein 4, soluble transferrin receptor, and thyroglobulin. Validations included repeated testing (n = 20 separately prepared experiments on 10 assay plates) in a single lab to assess precision and linearity. Seven independent laboratories tested 76 identical heparin plasma samples collected from a cohort of pregnant women in Niger using the same 7-plex assay to assess differences in results across laboratories. In the analytical validation experiments, intra- and inter-assay coefficients of variation were acceptable at <6% and <15% respectively and assay linearity was 96% to 99% with the exception of ferritin, which had marginal performance in some tests. Cross-laboratory comparisons showed generally good agreement between laboratories in all analyte results for the panel of 76 plasma specimens, with Lin's concordance correlation coefficient values averaging >= 0.8 for all analytes. Excluding plates that would fail routine quality control (QC) standards, the inter-assay variation was acceptable for all analytes except sTfR, which had an average inter-assay coefficient of variation of >= 20%. This initial cross-laboratory study demonstrates that the 7-plex test protocol can be implemented by users with some experience in immunoassay methods, but familiarity with the multiplexed protocol was not essential.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据