This study compared healthcare utilization up to 3 year follow-up in implantable cardioverter-defibrillator (ICD) patients with remote care compared to conventional care. The results showed that remote care was associated with a sustained lower rate of planned and unplanned healthcare utilization up to 3 subsequent years after ICD/CRT-D implantation, with no significant difference in one-year all-cause mortality.
Background Minimal evidence is available of the reduction in healthcare utilization of remote care in ICD patients over a longer period of follow-up. Objectives This study compared healthcare utilization up to 3 year follow-up in implantable cardioverter-defibrillator (ICD) patients with remote care compared to conventional care. Methods We conducted a retrospective cohort study of patients who received a single or dual-chamber ICD or cardiac resynchronization therapy-defibrillator (CRT-D) between 2016 and 2018. Patients with remote care and patients were compared with patients with received conventional care (control group). The primary endpoint was a composite of cardiac follow-up visits, ICD follow-up visits, telephone consultations, emergency department (ED) visits and hospital admissions and was defined as total healthcare utilization. The secondary endpoints were the individual care activities and one-year all-cause mortality. Results A total of 497 patients were included in the study, of which 299 patients were allocated to the remote care and 198 patients to the control group. Mean follow-up was 815 +/- 279 days. Remote care was associated with a significantly lower rate of adjusted total healthcare utilization in comparison to the control group that sustained for 3 subsequent follow-up years (IRR = 0.78, 95% CI [0.67 to 0.92], p < .01). One-year all-cause mortality was similar between the remote care and control group (respectively 3.0% vs. 5.5%, p = .29). Conclusions Compared to the standard follow-up of in-office care, a remote care program was associated with a sustained lower rate of planned and unplanned healthcare utilization up to 3 subsequent years after ICD/CRT-D implantation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据