4.6 Article

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

期刊

OPTICS EXPRESS
卷 30, 期 3, 页码 3926-3940

出版社

OPTICAL SOC AMER
DOI: 10.1364/OE.447041

关键词

-

类别

资金

  1. Major Scientific Research Project of Zhejiang Lab [2019MB0AE03]
  2. Foundation from Beijing Academy of Quantum Information Sciences [Y18G28]
  3. National Natural Science Foundation of China [61975005]

向作者/读者索取更多资源

The effects of magnetic field gradient on the sensitivity improvement of optical pumping magnetometers (OPMs) under extremely low magnetic field conditions were investigated. By modifying the magnetic field gradient relaxation model, the study determined the gradient relaxation time and spin polarizations, and verified the accuracy of the improved model through experimental results. The study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据