4.7 Article

High performance liquid analyte sensing based on Bloch surface wave resonances in the spectral domain

期刊

OPTICS AND LASER TECHNOLOGY
卷 145, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.optlastec.2021.107492

关键词

One-dimensional photonic crystal; Bloch surface wave; p- and s-polarized waves; Spectral reflectance and phase; Liquid analyte sensing; Figure of merit

资金

  1. Science and Research in the Moravia-Silesia Region [SP2021/64, RRC/10/2019]
  2. ERDF/ESF project New Composite Materials for Environmental Applications [CZ.02.1.01/0.0/0.0/17_048/0007399]

向作者/读者索取更多资源

The paper presents the design of a truncated one-dimensional photonic crystal comprising TiO2/SiO2 bi-layers for a highly sensitive liquid analyte sensor utilizing Bloch surface wave resonances. Experimental and theoretical results show that BSW resonances exhibit high sensitivity and performance metrics for both p- and s-polarized waves. This alternative to SPR sensors offers advantages of higher figure of merit and mechanical robustness, particularly evident in responses to aqueous solutions of NaCl across different refractive index ranges.
In this paper, we report a design of a truncated one-dimensional photonic crystal (1DPhC) comprising six bi-layers of TiO2/SiO2 with a termination layer of TiO2 to realize a highly sensitive liquid analyte sensor utiliz-ing Bloch surface wave (BSW) resonances in the spectral domain. We demonstrate that the BSW excitation shows up as a dip for both p- and s-polarized waves. Reflectance response for a p-polarized BSW is due to the spectral interference with maximum depth, and resonance thus obtained is comparable in magnitude with surface plasmon resonance (SPR). In the theoretical analysis, the spectral reflectance, phase difference and its derivative are determined for aqueous solutions of NaCl when the refractive index (RI) is changed in a range of 1.3330-1.3482. We revealed that the BSW resonances for the p-polarized wave give a sensitivity of 1602 nm per RI unit (RIU) and figure of merit (FOM) of 106 RIU-1, respectively. For an s-polarized BSW, they are increased to 1933 nm/RIU and 434 RIU-1, respectively. Moreover, the theoretical results are experimentally verified, and very good agreement is confirmed. The spectral responses for aqueous solutions of NaCl with the RI up to 1.3547 give for the p-polarized BSW a sensitivity of 2022 nm/RIU and FOM of 109 RIU-1, respectively, and using the spectral derivative of the BSW phase difference, the FOM is increased to 301 RIU-1. BSW based sensors with responses in both polarizations thus represent an effective alternative to SPR sensors with advantages including a higher FOM and mechanical robustness.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据