This study developed a multi-scale cascaded convolutional network for brain metastasis detection and validated its accuracy. The results showed that using this system can improve the detection sensitivity of doctors and reduce reading time.
Background Accurate detection is essential for brain metastasis (BM) management, but manual identification is laborious. This study developed, validated, and evaluated a BM detection (BMD) system. Methods Five hundred seventy-three consecutive patients (10 448 lesions) with newly diagnosed BMs and 377 patients without BMs were retrospectively enrolled to develop a multi-scale cascaded convolutional network using 3D-enhanced T1-weighted MR images. BMD was validated using a prospective validation set comprising an internal set (46 patients with 349 lesions; 44 patients without BMs) and three external sets (102 patients with 717 lesions; 108 patients without BMs). The lesion-based detection sensitivity and the number of false positives (FPs) per patient were analyzed. The detection sensitivity and reading time of three trainees and three experienced radiologists from three hospitals were evaluated using the validation set. Results The detection sensitivity and FPs were 95.8% and 0.39 in the test set, 96.0% and 0.27 in the internal validation set, and ranged from 88.9% to 95.5% and 0.29 to 0.66 in the external sets. The BMD system achieved higher detection sensitivity (93.2% [95% CI, 91.6-94.7%]) than all radiologists without BMD (ranging from 68.5% [95% CI, 65.7-71.3%] to 80.4% [95% CI, 78.0-82.8%], all P < .001). Radiologist detection sensitivity improved with BMD, reaching 92.7% to 95.0%. The mean reading time was reduced by 47% for trainees and 32% for experienced radiologists assisted by BMD relative to that without BMD. Conclusions BMD enables accurate BM detection. Reading with BMD improves radiologists' detection sensitivity and reduces their reading times.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据