4.8 Article

Effects of nanostructuration on the electrochemical performance of metallic bioelectrodes

期刊

NANOSCALE
卷 14, 期 8, 页码 3179-3190

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1nr06280h

关键词

-

资金

  1. European Commission [793102-NeuPES-H2020-MSCA-IF-2017]
  2. Comunidad de Madrid [2019-T1/IND-1335]
  3. CSIC [LINKA20342]
  4. CM [S2018/NMT-4291 TEC2SPACE]
  5. MINECO [CSIC13-4E-1794]
  6. EU (FEDER, FSE)
  7. [MAT2017-86450-c4-3-r]

向作者/读者索取更多资源

The use of metallic nanostructures in bioelectrode fabrication is gaining attention due to their potential benefits in surface area and electrochemical performance. This study introduces a versatile fabrication method for metallic nanocolumnar structures (NCs) and thin films (TFs) from Ti, Au, and Pt. The results show that NCs significantly reduce impedance and have higher charge storage capacity compared to TFs. Circuit simulations demonstrate that NCs provide less filtered signals in voltage-controlled systems and safer stimulation conditions in current-controlled systems. Additionally, NCs exhibit more stable electrochemical properties compared to TFs, making them promising for in vivo use.
The use of metallic nanostructures in the fabrication of bioelectrodes (e.g., neural implants) is gaining attention nowadays. Nanostructures provide increased surface area that might benefit the performance of bioelectrodes. However, there is a need for comprehensive studies that assess electrochemical performance of nanostructured surfaces in physiological and relevant working conditions. Here, we introduce a versatile scalable fabrication method based on magnetron sputtering to develop analogous metallic nanocolumnar structures (NCs) and thin films (TFs) from Ti, Au, and Pt. We show that NCs contribute significantly to reduce the impedance of metallic surfaces. Charge storage capacity of Pt NCs is remarkably higher than that of Pt TFs and that of the other metals in both morphologies. Circuit simulations of the electrode/electrolyte interface show that the signal delivered in voltage-controlled systems is less filtered when nanocolumns are used. In a current-controlled system, simulation shows that NCs provide safer stimulation conditions compared to TFs. We have assessed the durability of NCs and TFs for potential use in vivo by reactive accelerated aging test, mimicking one-year in vivo implantation. Although each metal/morphology reveals a unique response to aging, NCs show overall more stable electrochemical properties compared to TFs in spite of their porous structure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据