4.6 Article

Application of HPLC-QQQ-MS/MS and New RP-HPLC-DAD System Utilizing the Chaotropic Effect for Determination of Nicotine and Its Major Metabolites Cotinine, and trans-3′-Hydroxycotinine in Human Plasma Samples

期刊

MOLECULES
卷 27, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/molecules27030682

关键词

nicotine; cotinine; trans-3 '-hydroxycotinine; RP-HPLC-DAD; HPLC-QQQ-MS/ ; MS chaotropic effect

向作者/读者索取更多资源

This study developed and compared two new chromatographic methods, HPLC-QQQ-MS/MS and RP-HPLC-DAD enriched with chaotropic additives, for the determination of nicotine and its major metabolites in human plasma. The results showed that HPLC-QQQ-MS/MS had lower limits of detection, while RP-HPLC-DAD enriched with chaotropic additives had higher extraction efficiency.
The routine techniques currently applied for the determination of nicotine and its major metabolites, cotinine, and trans-3 & PRIME;-hydroxycotinine, in biological fluids, include spectrophotometric, immunoassays, and chromatographic techniques. The aim of this study was to develop, and compare two new chromatographic methods high-performance liquid chromatography coupled to triple quadrupole mass spectrometry (HPLC-QQQ-MS/MS), and RP-HPLC enriched with chaotropic additives, which would allow reliable confirmation of tobacco smoke exposure in toxicological and epidemiological studies. The concentrations of analytes were determined in human plasma as the sample matrix. The methods were compared in terms of the linearity, accuracy, repeatability, detection and quantification limits (LOD and LOQ), and recovery. The obtained validation parameters met the ICH requirements for both proposed procedures. However, the limits of detection (LOD) were much better for HPLC-QQQ-MS/MS (0.07 ng mL(-1) for trans-3 & PRIME;-hydroxcotinine; 0.02 ng mL(-1) for cotinine; 0.04 ng mL(-1) for nicotine) in comparison to the RP-HPLC-DAD enriched with chaotropic additives (1.47 ng mL(-1) for trans-3 & PRIME;-hydroxcotinine; 1.59 ng mL(-1) for cotinine; 1.50 ng mL(-1) for nicotine). The extraction efficiency (%) was concentration-dependent and ranged between 96.66% and 99.39% for RP-HPLC-DAD and 76.8% to 96.4% for HPLC-QQQ-MS/MS. The usefulness of the elaborated analytical methods was checked on the example of the analysis of a blood sample taken from a tobacco smoker. The nicotine, cotinine, and trans-3 & PRIME;-hydroxycotinine contents in the smoker's plasma quantified by the RP-HPLC-DAD method differed from the values measured by the HPLC-QQQ-MS/MS. However, the relative errors of measurements were smaller than 10% (6.80%, 6.72%, 2.04% respectively).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据