4.5 Article

Complement ratios C3bc/C3 and sC5b-9/C5 do not increase the sensitivity of detecting acute complement activation systemically

期刊

MOLECULAR IMMUNOLOGY
卷 141, 期 -, 页码 273-279

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.molimm.2021.11.016

关键词

Complement activation products; Ratio; C3bc; sC5b-9; Complement; Systemic compplement activation

向作者/读者索取更多资源

This study found that C3bc and sC5b-9 are sensitive markers for complement activation. However, the ratios of C3bc/C3 and sC5b-9/C5 did not improve the detection of systemic complement activation compared to the activation product alone.
Background: Complement activation plays an important pathogenic role in numerous diseases. The ratio between an activation product and its parent protein is suggested to be more sensitive to detect complement activation than the activation product itself. In the present study we explored whether the ratio between the activation product and the parent protein for C3 (C3bc/C3) and for C5 (sC5b-9/C5) increased the sensitivity to detect complement activation in acute clinical settings compared to the activation product alone. Materials and methods: Samples from patients with acute heart failure following ST-elevated myocardial infarction (STEMI) and from patients with out-of-hospital cardiac arrest (OHCA) were used. C3, C3bc and C5, sC5b-9 were analysed in 629 and 672 patient samples, respectively. Healthy controls (n = 20) served to determine reference cut-off values for activation products and ratios, defined as two SD above the mean. Results: Increased C3bc/C3- and sC5b-9/C5 ratios were vastly dependent on C3bc and sC5b-9. Thus, 99.5 % and 98.1 % of the increased C3bc/C3- and sC5b-9/C5 ratios were solely dependent on increased C3bc and sC5b-9, respectively. Significantly decreased C3 and C5 caused increased ratios in only 3/600 (0.5 %) and 4/319 (1.3 %) samples, respectively. Strong correlations between C3bc and C3bc/C3-ratio and between sC5b-9 and sC5b-9/ C5-ratio were found in the STEMI- (r = 0.926 and r = 0.786, respectively) and the OHCA-population (r = 0.908 and r = 0.843, respectively; p < 0.0001 for all). Importantly, sC5b-9 identified worse outcome groups better than sC 5b- 9/C 5-ratio. Conclusion: C3bc and sC5b-9 were sensitive markers of complement activation. The ratios of C3bc/C3 and sC5b9/C5 did not improve detection of complement activation systemically.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据