4.7 Article

Ternary electrochemiluminescence biosensor based on black phosphorus quantum dots doped perylene derivative and metal organic frameworks as a coreaction accelerator for the detection of chloramphenicol

期刊

MICROCHEMICAL JOURNAL
卷 172, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2021.106927

关键词

Electrochemiluminescence; Chloramphenicol; Black phosphorous; Aptamer biosensor; PTC-NH2

资金

  1. National Natural Science Foundation of China [51874050, 21904014]
  2. Jiangsu Higher Education Institutions of China [19KJB150003]
  3. Natural Science Foundation of Jiangsu Province of China [BK20190928]
  4. Foundation of Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology of China [BM2012110]
  5. Postgraduate Research & Practice Innovation Program of Jiangsu Province of China [SJCX21_1215]

向作者/读者索取更多资源

A sensitive and selective electrochemiluminescence (ECL) aptasensor was developed for chloramphenicol (CAP) detection using a metal-organic frameworks (Co-Ni/MOF) enhancing mechanism. The aptasensor showed signal amplification and specific recognition function, enabling detection of CAP at low concentrations.
In this work, a sensitive and selective electrochemiluminescence (ECL) aptasensor was developed using an enhancing mechanism of the metal-organic frameworks (Co-Ni/MOF) in the perylene derivative (BP/PTC-NH2)/peroxydisulfate (S2O82-) system for chloramphenicol (CAP) assay. Firstly, black phosphorus quantum dots (BPQDs) were synthesized and added into the precursor solution of PTC-NH2 to synthesize BPQDs doped PTC-NH2 nanoparticles (BP/PTC-NH2), which were acted as the ECL emitters. Co-Ni/MOF with excellent encapsulation effect and catalytic effect, can react with co-reactants (K2S2O8) to produce more SO4 center dot-, thus the ECL signal of the compound was obviously raised by 3.8 times greater than single BP/PTC-NH2, achieving signal amplification of the ECL system. In the presence of chloramphenicol, we can see a considerable enhancement of signal, it could be attributed to aptamer recognition resulted the aptamer pulling down from the sensing interface by CAP. Therefore, based on this enhancement effect and the specific recognition function of aptamer, a sensitive ECL aptamer sensor was designed for CAP detection. Under optimal conditions, the aptasensor can quantify the concentration of CAP from 1.0 x 10(-13) to 1.0 x 10(-6) M with low limit of detection of 2.9 x 10(-14) M (S/N = 3). Besides, the developed ECL aptasensor could selectively detect CAP in a mixture containing CAP interference compounds, which demonstrated its potential to detect other antibiotics in aquatic environment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据