4.7 Article

Fluorene based fluorescent and colorimetric chemosensors for selective detection of cyanide ions in aqueous medium and application of logic gate

期刊

MICROCHEMICAL JOURNAL
卷 173, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2021.107018

关键词

Knoevenagel condensation; Suzuki coupling; Cyanide; Chemosensor; Logic gate

资金

  1. Pakistan Science Foundation [PSF/NSFC-II/Eng/KP-COMSATS-Abt (12)]

向作者/读者索取更多资源

Two fluorene-based chemosensors 1 and 2 were developed through the Suzuki-Miyaura coupling reaction for sensitive detection of cyanide ions, showing excellent linear response in the Benesi-Hildebrand plot for selective detection of cyanide.
Rising detrimental effects of cyanide due to its frequent large-scale utilization demand rapid and sensitive detection of cyanide ions. Herein, two new fluorene based chemosensors 1 and 2 have been developed through the Suzuki-Miyaura coupling reaction for fluorescence enhancement based selective detection of cyanide with sensitivity levels down to 0.2 ppb and 0.4 ppb, respectively. The plausible sensing mechanism is based on Michael type adduct formation due to the reaction of cyanide with chemosensors and was confirmed by H-1 NMR titration, Job's plot, dynamic light scattering (DLS), and density functional theory (DFT) calculations. Chemo-sensors 1 and 2 showed excellent linear response towards CN- ions (0-100 nM) in the Benesi-Hildebrand plot with association constants (K-a) 1.61 x 10(6) and 7.1 x 10(5) M-1, respectively that corresponds to their favorable chemical reaction. Excellent selectivity of chemosensors for cyanide in the presence of other interferences was investigated through fluorescence emission, UV-Visible, and DFT analysis. Surprisingly, an immediate reversible colorimetric change upon alternate shaking and steadiness of chemosensor - CN- solution was noticed indicating that chemosensors can act as promising recyclable sensors for colorimetric on-site detection of CN-. Meanwhile, chemosensors 1 and 2 displayed highly selective colorimetric detection of CN- under daylight and UV radiations (365 nm). Further, cyanide responsive test kits were fabricated that provided a low-cost and portable method for on-site detection of CN- ions in an aqueous medium. Finally, chemosensors were successfully applied for designing logic gates, and detection of cyanide in industrial waste and food samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据