4.7 Article

A novel stability-indicating HPLC-DAD method for determination of favipiravir, a potential antiviral drug for COVID-19 treatment; application to degradation kinetic studies and in-vitro dissolution profiling

期刊

MICROCHEMICAL JOURNAL
卷 172, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2021.106917

关键词

COVID-19; Favipiravir; HPLC-DAD; Mass spectrometry; SIAM; Kinetic Study; Dissolution Profiling

向作者/读者索取更多资源

A stabilityindicating HPLC-DAD method was developed and validated for determination of favipiravir under different stress conditions, showing its susceptibility to acid, base hydrolysis, and oxidative degradation. Mass spectrometry was used for structure elucidation of forced degradation products, and effective separation of FAV and its degradation products was achieved on a Zorbax C18 column. The proposed method proved to be accurate, reliable, time-saving, and cost-effective for regular quality control and stability assessment of FAV in tablet form.
Modern pharmaceutical analysis is paying a lot of attention to the stability of novel drug formulations as well as establishment of suitable stability-indicating approaches. In the current work, a comprehensive stabilityindicating HPLC-DAD method has been developed and validated for determination of favipiravir (FAV) which is a novel and emerging antiviral option in COVID-19 treatment. The stability of FAV was examined under different stress conditions. FAV was found to be susceptible to acid, base hydrolysis and oxidative degradation. Structure elucidation of the forced degradation products was carried out using mass spectrometry (MS) operated in electrospray ionization mode. Effective separation of FAV and its induced degradation products was achieved using isocratic elution mode on Zorbax C18 column maintained at 30 degrees C. The mobile phase used was comprised of 25.0 mM phosphate buffer (pH 3.5 +/- 0.05) containing 0.1% (w/v) heptane sulphonic acid sodium salt-methanol-acetonitrile (62:28:10, by volume), delivered at flow rate of 1.0 mL/min. The diode array detector signal for FAV was monitored at 321.0 nm over a concentration range of 6.25-250.00 mu g/mL. The potential mechanisms for generation of degradation products were postulated through comparison of MS1 fragmentation pattern of FAV and its degradation products. Moreover, the proposed method was also extended to study the degradation kinetics. Additionally, dissolution profiling of FAV in different media was monitored. Clearly, the suggested approach is accurate, reliable, time-saving, and cost-effective. As a result, it may be utilized for regular quality control and stability assessment of FAV in its tablet dosage form.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据