Dose kernel decomposition for spot-based radiotherapy treatment planning

期刊

MEDICAL PHYSICS
卷 49, 期 2, 页码 1196-1208

出版社

WILEY
DOI: 10.1002/mp.15415

关键词

Gamma Knife; Gamma Pod; kernel decomposition

资金

  1. National Science Foundation [R01 CA235723, R01 CA218402]

向作者/读者索取更多资源

The proposed kernel decomposition model provides accurate and real-time dose calculations for spot-based radiotherapies like GK and GP, without the need for pre-calculation or large data storage. It allows for efficient global fine search for optimal spots during treatment planning, demonstrating high passing rates in comparison to MC and TPS calculations for clinical plans.
Purpose Pre-calculation of accurate dose deposition kernels for treatment planning of spot-based radiotherapies, such as Gamma Knife (GK) and Gamma Pod (GP), can be very time-consuming and may require large data storage with an enormous number of possible spots. We proposed a novel kernel decomposition (KD) model to address accurate and fast (real-time) dose calculation with reduced data storage requirements for spot-based treatment planning. The application of the KD model was demonstrated for clinical GK and GP radiotherapy platforms. Methods The dose deposition kernel at each spot (shot position) is modeled as the product of a shift-invariant kernel based on a reference kernel and spatially variant scale factor. The reference kernel, one for each collimator, is defined at the center of the commissioning phantom for GK and at the center of the treatment target for GP and calculated using the Monte Carlo (MC) method. The spatially variant scale factor is defined as the ratio of the mean tissue maximum ratio (TMR) at the candidate shot position to that at the reference kernel position, and the mean TMR map is calculated within the entire volume through parallel beam ray tracing on the density image followed by averaging over all source directions. The proposed KD dose calculations were compared with the MC method and with the GK and GP treatment planning system (TPS) computations for various shot positions and collimator sizes utilizing a phantom and 14 and 12 clinical plans for GK and GP, respectively. Results For the phantom study, the KD Gamma index (3%/1 mm) passing rates were greater than 99% (median 100%) relative to the MC doses, except for the shots close to the boundary. The passing rates dropped below 90% for 8 mm (16 mm) shots positioned within similar to 1 cm (similar to 2 cm) of the boundary. For the clinical GK plans, the KD Gamma passing rates were greater than 99% (median 100%) compared to the MC and greater than 92% (median 99%) compared to the TPS. For the clinical GP plans, the KD Gamma passing rates were greater than 95% (median 98%) compared to the MC and greater than 91% (median 97%) compared to the TPS. The scale factors were calculated in sub-seconds with GPU implementation and only need to be calculated once before treatment plan optimization. The calculation of the dose kernel was also within sub-seconds without requiring beam-by-beam calculation commonly done in the TPS. Conclusion The proposed model can provide an accurate dose and enables real-time dose and derivative calculations by kernel shifting and scaling without pre-calculating or requiring large data storage for GK and GP dose deposition kernels during treatment planning. This model could be useful for spot-based radiotherapy treatment planning by allowing an efficient global fine search for optimal spots.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据