4.6 Article

Electrocatalytic Activity Enhancement Using Graphene-Metal Oxide Nanocomposites for the Ultra Low Level Detection of Biomolecules

期刊

出版社

ELECTROCHEMICAL SOC INC
DOI: 10.1149/1945-7111/ac50de

关键词

-

资金

  1. KSCSTE-SARD program of the Kerala State Council for Science, Technology, and Environment, Kerala Government (KSCSTE) [KSCSTE/5253/2017/SARD]
  2. DST-FIST scheme for Colleges (Level 1) of the Department of Science and Technology, Government of India [SR/FST/College-289/2015]
  3. DBT STAR College Scheme of the Department of Biotechnology, Government of India [BT/HRD/11/01/2019]
  4. KSCSTE-SARD program of S. N College, Kannur
  5. Kannur University

向作者/读者索取更多资源

Metal oxide/reduced graphene oxide (MO/RGO) nanocomposites were synthesized using a hydrothermal method, and modified electrochemical sensors based on these composites were developed for the sensitive detection of biomolecules. The NiO/RGO/CPE sensor showed superior performance and a lower detection limit for the analytes compared to other modified electrodes.
Metal oxide/reduced graphene oxide (MO/RGO, MO = NiO, Co3O4, and SnO2) nanocomposites were synthesized by a cost-effective hydrothermal method. The structural, thermal, and morphological characteristics of composites were investigated using PXRD, FT-IR, TGA, Raman, SEM, and HR-TEM. Modified carbon paste electrochemical sensors based on NiO/RGO, Co3O4/RGO, and SnO2/RGO were developed and compared for the effective detection of Epinephrine (EPN), Serotonin (SER), and Tyrosine (TYR). The performance of the NiO/RGO/CPE sensor was superior to other composites modified electrodes. The electrochemical measurements were studied by cyclic voltammetry, differential pulse voltammetry, chronoamperometry, and electrochemical impedance spectroscopy. The modified electrodes showed excellent electrocatalytic activity towards EPN, SER, and TYR arising from the synergistic effect of reduced graphene oxide and metal oxide. The excellent electrical conductivity imparted by direct interphase of RGO to semiconductive metal oxide, increased surface area, and the increased number of active sites favor the sensitive determination of biomolecules. The NiO/RGO/CPE facilitated the analysis of EPN, SER, and TYR with a lower detection limit of 158 pM, 165 pM, and 519 pM respectively. The peaks for the three biomolecules are well separated from each other and the electrodes were effectively used for real samples. (C) 2022 The Electrochemical Society (ECS). Published on behalf of ECS by IOP Publishing Limited.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据