4.3 Article

Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis

期刊

JOURNAL OF RADIATION RESEARCH
卷 62, 期 6, 页码 1114-1119

出版社

OXFORD UNIV PRESS
DOI: 10.1093/jrr/rrab092

关键词

brain metastases; stereotactic radiosurgery (SRS); volumetric modulated arc therapy (VMAT); conformity index (CI)

资金

  1. JSPS KAKENHI [21 K15548]
  2. commissioned project of Varian Medical Systems

向作者/读者索取更多资源

Comparing DCAT, CoVMAT, and NcVMAT plans in the treatment of single brain metastasis, it was found that NcVMAT significantly improved target conformity and reduced doses to normal brain tissue.
In the delivery of stereotactic radiosurgery (SRS) by linear accelerator (LINAC), dynamic conformal arc therapy (DCAT) with non-coplanar beams is conventionally used. However, volumetric modulated arc therapy (VMAT) can improve target conformity, thereby decreasing the dose to organs at risk by inversed planning methods, but few studies have directly compared DCAT and VMAT with and without non-coplanar beams in patients with single brain metastasis. We therefore conducted a planning study to compare the dose distribution in DCAT, VMAT using only a coplanar arc (CoVMAT) and VMAT with non-coplanar arcs (NcVMAT) in the treatment of single brain metastasis. DCAT, CoVMAT and NcVMAT plans were created for 15 patients. The three modalities were compared in terms of target conformity, target coverage, the dose to normal brain tissue, monitor units (MUs) and beam-on time. Both conformity indices (RTOG-CI and IP-CI) as well as the D-98% of the gross target volume (GTV) were significantly better in the NcVMAT plans than in the DCAT plans. Comparisons of the doses to normal brain tissue revealed that the V-20Gy, V-15Gy, V-12Gy, V-10Gy and V-5Gy were significantly smaller in the NcVMAT plans than in the plans based on the other two modalities. The MUs of the DCAT and NcVMAT plans were larger than those of the CoVMAT plans, and the beam-on time was longer in the NcVMAT and CoVMAT plans than in the DCAT plans. Compared to the CoVMAT and DCAT plans, NcVMAT plans significantly improved target conformity and reduced the doses to normal brain tissue at V-20Gy, V-15Gy, V-12Gy, V-10Gy and V-5Gy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据