Effect of additional reference objects on accuracy of five intraoral scanners in partially and completely edentulous jaws: An in vitro study

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 130, 期 1, 页码 111-118

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.prosdent.2021.09.032

关键词

-

向作者/读者索取更多资源

The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients was investigated. The results showed that the additional artificial landmark technique improved the trueness of all measured parameters in partially edentulous models. However, the effect of additional artificial landmarks on the accuracy of digital scans was limited in completely edentulous areas.
Statement of problem. The effect of additional reference objects on the accuracy of different intraoral scanners for partially and completely edentulous patients has not been investigated sufficiently.Purpose. The purpose of this in vitro study was to evaluate the effect of an additional reference object in the form of additional artificial landmarks on the trueness and precision of different intraoral scanners in partially and completely edentulous areas.Material and methods. Partially and completely edentulous models with 2 and 4 implants (BLT, RC, Institut Straumann AG), respectively, were used in the study. For the digital scan, scan bodies (CARES Mono Scanbody) were attached, and reference data obtained by using industrial scanners. Ten digital scans of the same model were made with each intraoral scanner: PRIMESCAN, TRIOS 3, TRIOS 4, Carestream 3600, and Medit. Then, additional artificial landmarks were attached, and 10 more intraoral scans were made with each device. Computer-aided design files of the scan bodies were aligned to obtain 3-dimensional surfaces with reference and test scanners. Trueness and precision of distance, angulations, and vertical shift between scan bodies were estimated. The Mann-Whitney Wilcoxon or Student 2-sample t test was applied to estimate statistically significant differences between groups (a=.05).Results. In the partially edentulous model, distance trueness mean & PLUSMN;standard deviation values ranged from -46.7 & PLUSMN;15.4 gm (TRIOS 3) to 392.1 & PLUSMN;314.3 gm (Medit) in models without additional artificial landmarks. When additional artificial landmarks were applied, trueness of distance mean & PLUSMN;standard deviation values ranged between -35 & PLUSMN;13 gm (TRIOS 4) and 117.7 & PLUSMN;232.3 gm (CARESTREAM). Trueness mean & PLUSMN;standard deviation values of angulation varied from -0.0 & PLUSMN;0.5 degrees (CARESTREAM) to 0.2 & PLUSMN;0.0 degrees (PRIMESCAN) without additional artificial landmarks and from 0.0 & PLUSMN;0.2 degrees (TRIOS 3) to 0.4 & PLUSMN;0.5 degrees (CARESTREAM) with additional artificial landmarks. Vertical shift trueness measurements varied from -108 & PLUSMN;47.1 gm (TRIOS 4) to 107.2 & PLUSMN;103.5 gm (Medit) without additional artificial landmarks and from -15.0 & PLUSMN;45.0 gm (CARESTREAM) to -86.9 & PLUSMN;42.1 gm (TRIOS 4) with additional artificial landmarks. The additional artificial landmark technique improved the trueness of all measured parameters for the 5 tested intraoral scanners. No statistically significant differences were found among models with or without additional artificial landmarks, except for Medit in all parameters and PRIMESCAN in angle measurements (P<.05). The best precision for distance was found with TRIOS 3 and with PRIMESCAN for angulation and vertical shift. Larger deviations were observed in the completely edentulous situation. The effect of additional artificial landmarks was limited when the accuracy parameters of digital scans were considered.Conclusions. Scans with and without additional artificial landmarks of partially edentulous conditions scanned by any of the intraoral scanners tested did not influence precision and trueness, except for Medit i500 in the distance and vertical shift parameters and CARESTREAM3600 in vertical shift. Precision and trueness of digital scans of completely edentulous areas were affected, except for Medit i500 for distance, PRIMESCAN and TRIOS 4 for angle, and all systems except TRIOS 4 for vertical shift precision. (J Prosthet Dent 2023;130:111-8)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据