4.5 Article

Evaluation of Benzylpenicillin as an Internal Standard for Measurement of Piperacillin Bone Concentrations Via Microdialysis

期刊

JOURNAL OF PHARMACEUTICAL SCIENCES
卷 110, 期 10, 页码 3500-3506

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.xphs.2021.06.008

关键词

Antiinfective(s); Piperacillin; Microdialysis; Tissue concentrations; Pharmacokinetics; HPLC

资金

  1. Novo Nordisk Foundation
  2. Kirsten and Freddy Johansen Foundation
  3. Inge and Asker Larsen Foundation
  4. Carl and Ellen Hertz Legat Foundation

向作者/读者索取更多资源

The study indicates that benzylpenicillin is suitable as an internal standard for piperacillin in microdialysis studies. The mean fT>MIC (16 mg/mL) reached a target of 50% fT>MIC, but not all pigs in all compartments achieved this target. Different strategies must be considered for higher targets to be met.
Microdialysis is a pharmacokinetic tool that can be advantageous when obtaining tissues' pharmacokinetic information. Since absolute extracellular tissue concentrations are needed in pharmacokinetic studies, calibrating the microdialysis system is necessary. The internal standard method is superior when compared to other calibration methods. However, thorough evaluation of the internal standard is required before it can be used. In vitro experiments and an in vivo study on pigs (n = 8) were conducted to assess the relative recoveries by gain and by loss for piperacillin, both with and without a benzylpenicillin concentration of 5 mg/mL. Furthermore, the in vivo setup allowed for an evaluation of piperacillin cancellous bone and subcutaneous tissue concentrations in a single 8 h dosing interval. Ultra-high performance liquid chromatography (UHPLC) was used to determine piperacillin and benzylpenicillin concentrations. Relative recovery by loss for benzylpenicillin and relative recovery by gain for piperacillin were similar in in vitro and in vivo. Presence of benzylpenicillin did not affect the relative recovery for piperacillin. Relative recovery, pharmacokinetic parameters and fT>MIC were similar when comparing the retrodialysis by drug and the internal standard calibration methods (p > 0.31). Mean fT>MIC (16 mg/mL) for plasma, cancellous bone and subcutaneous tissue were 232 min, 255 min and 295 min, respectively. Our findings suggest that benzylpenicillin is suitable as an internal standard for piperacillin in microdialysis studies. Mean fT>MIC (16 mg/mL) for plasma, cancellous bone, and subcutaneous tissue reached a target of 50% fT>MIC under the investigated conditions (mean range: 52%-66%); however, the target was not obtained in all pigs in all compartments. Moreover, 100% fT>MIC was not obtained in any case, suggesting that different strategies must be taken into consideration if higher targets are employed. (C) 2021 The Authors. Published by Elsevier Inc. on behalf of American Pharmacists Association.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据