4.3 Article

Predictors and Outcomes of Fully Covered Stent Treatment for Anastomotic Esophageal Strictures in Esophageal Atresia

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MPG.0000000000003330

关键词

anastomotic stricture; endoscopy; esophageal atresia; esophageal stent; esophageal stricture; esophagus; gastroenterology; long gap esophageal atresia; pediatrics

向作者/读者索取更多资源

Esophageal stenting can be successful in preventing anastomotic strictures following surgical repair in pediatric patients with esophageal atresia. The change in luminal diameter after stenting is the most significant predictor of stent success.
Background and Aims: Anastomotic strictures following surgical repair is one of the most common complications in esophageal atresia (EA). The utility of esophageal stenting to treat anastomotic esophageal strictures in pediatrics is unclear. Our primary aim was to evaluate whether esophageal stenting, in conjunction with dilation and other endoscopic therapies, prevented surgical stricture resection (SR). Our secondary aims were to evaluate predictors of successful esophageal stenting and evaluate adverse events from stent placement. Methods: A retrospective review of pediatric patients with EA complicated by esophageal strictures was performed. The change in stricture diameter in millimeters from the time of stent removal to subsequent endoscopy was defined as delta diameter (Delta D). A receiver operating characteristic (ROC) curve analysis was performed to determine the discriminatory ability of Delta D. Youden J index was used to identify optimal cutoff-point in predicting stent success. A univariate and multivariate analysis were done to assess predictors of success. Result: Forty-nine esophageal anastomoses were stented to treat esophageal strictures. Stents prevented SR in 41% of patients. ROC curve analysis utilizing Youden J index identified Delta D of <= 4 mm (area under the curve = 0.790; 95% confidence interval: 0.655-0.924; P < 0.001) as the optimal cutoff point in differentiating stent success. The most common adverse events were erosions/ulcerations, granulation tissue formation, and vomiting/retching. Conclusion: Stent therapy in preventing SR at the site of EA repair was successful in 41% in our population with good long term follow-up. The most significant predictor of success in this study was the change in luminal diameter (<= 4 mm) at initial poststent follow-up.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据