期刊
JOURNAL OF ORTHOPAEDIC TRAUMA
卷 36, 期 -, 页码 S32-S39出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BOT.0000000000002307
关键词
biomarkers; fracture healing; collagen X; tibial plateau
资金
- AO Trauma North America
- Orthopaedic Research and Education Foundation
- Gerlinger Foundation
- UCSF New Orthopaedic Vision Award
- Donna Giordano
This study aims to monitor serum concentrations of collagen X in patients with isolated tibial plateau fractures using a novel bioassay. The results demonstrate a significant increase in collagen X levels after fractures, but the increase is delayed in cases of staged fixation.
Objectives: To use a novel, validated bioassay to monitor serum concentrations of a breakdown product of collagen X in a prospective longitudinal study of patients sustaining isolated tibial plateau fractures. Collagen X is the hallmark extracellular matrix protein present during conversion of soft, cartilaginous callus to bone during endochondral repair. Previous preclinical and clinical studies demonstrated a distinct peak in collagen X biomarker (CXM) bioassay levels after long bone fractures. Setting: Level 1 academic trauma facility. Patients/Participants: Thirty-six patients; isolated tibial plateau fractures. Intervention: (3) Closed treatment, ex-fix (temporizing/definitive), and open reduction internal fixation. Main Outcome Measurements: Collagen X serum biomarker levels (CXM bioassay). Results: Twenty-two men and 14 women (average age: 46.3 y; 22.6-73.4, SD 13.3) enrolled (16 unicondylar and 20 bicondylar fractures). Twenty-five patients (72.2%) were treated operatively, including 12 (33.3%) provisionally or definitively treated by exfix. No difference was found in peak CXM values between sexes or age. Patients demonstrated peak expression near 1000 pg/mL (average: male-986.5 pg/mL, SD 369; female-953.2 pg/mL, SD 576). There was no difference in peak CXM by treatment protocol, external fixator use, or fracture severity (Schatzker). Patients treated with external fixation (P = 0.05) or staged open reduction internal fixation (P = 0.046) critically demonstrated delayed peaks. Conclusions: Pilot analysis demonstrates a strong CXM peak after fractures commensurate with previous preclinical and clinical studies, which was delayed with staged fixation. This may represent the consequence of delayed construct loading. Further validation requires larger cohorts and long-term follow-up. Collagen X may provide an opportunity to support prospective interventional studies testing novel orthobiologics or fixation techniques.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐