Clinical accuracy and initial experience with augmented reality-assisted pedicle screw placement: the first 205 screws

期刊

JOURNAL OF NEUROSURGERY-SPINE
卷 36, 期 3, 页码 351-357

出版社

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/2021.2.SPINE202097

关键词

augmented reality; AR; mixed reality; computer-assisted spine surgery; spine navigation; pedicle screw; accuracy; surgical technique

向作者/读者索取更多资源

This study investigated the application of augmented reality (AR) technology in spine surgery and demonstrated the high accuracy achieved by using a unique head-mounted display navigation system. The consecutive placement of 205 pedicle screws resulted in a high accuracy rate, indicating that AR technology can be effectively, safely, and accurately used for spinal instrumentation placement.
OBJECTIVE Augmented reality (AR) is a novel technology which, when applied to spine surgery, offers the potential for efficient, safe, and accurate placement of spinal instrumentation. The authors report the accuracy of the first 205 pedicle screws consecutively placed at their institution by using AR assistance with a unique head-mounted display (HMD) navigation system. METHODS A retrospective review was performed of the first 28 consecutive patients who underwent AR-assisted pedicle screw placement in the thoracic, lumbar, and/or sacral spine at the authors' institution. Clinical accuracy for each pedicle screw was graded using the Gertzbein-Robbins scale by an independent neuroradiologist working in a blinded fashion. RESULTS Twenty-eight consecutive patients underwent thoracic, lumbar, or sacral pedicle screw placement with AR assistance. The median age at the time of surgery was 62.5 (IQR 13.8) years and the median body mass index was 31 (IQR 8.6) kg/m(2). Indications for surgery included degenerative disease (n = 12, 43%); deformity correction (n = 12, 43%); tumor (n = 3, 11%); and trauma (n = 1, 4%). The majority of patients (n = 26, 93%) presented with low-back pain, 19 (68%) patients presented with radicular leg pain, and 10 (36%) patients had documented lower extremity weakness. A total of 205 screws were consecutively placed, with 112 (55%) placed in the lumbar spine, 67 (33%) in the thoracic spine, and 26 (13%) at S1. Screw placement accuracy was 98.5% for thoracic screws, 97.8% for lumbar/S1 screws, and 98.0% overall. CONCLUSIONS AR depicted through a unique HMD is a novel and clinically accurate technology for the navigated insertion of pedicle screws. The authors describe the first 205 AR-assisted thoracic, lumbar, and sacral pedicle screws consecutively placed at their institution with an accuracy of 98.0% as determined by a Gertzbein-Robbins grade of A or B.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据